Optimalizace času akvizice diagnostické celotělové scintigrafie 131I u pacientů s diferencovanými karcinomy štítné žlázy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F22%3A73612478" target="_blank" >RIV/61989592:15110/22:73612478 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.prolekare.cz/casopisy/nuklearni-medicina/2022-1-17/optimalizace-casu-akvizice-diagnosticke-celotelove-scintigrafie-131i-u-pacientu-s-diferencovanymi-karcinomy-stitne-zlazy-130395" target="_blank" >https://www.prolekare.cz/casopisy/nuklearni-medicina/2022-1-17/optimalizace-casu-akvizice-diagnosticke-celotelove-scintigrafie-131i-u-pacientu-s-diferencovanymi-karcinomy-stitne-zlazy-130395</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Optimalizace času akvizice diagnostické celotělové scintigrafie 131I u pacientů s diferencovanými karcinomy štítné žlázy
Popis výsledku v původním jazyce
Diagnostická celotělová scintigrafie 131I u pacientů s diferencovanými karcinomy štítné žlázy je důležitým krokem k ověření radiojódavity tkáně před podáním terapie 131I.
Název v anglickém jazyce
Optimization of the timing of the whole body diagnostic scintigraphy with 131I in patients with differentiated thyroid cancers
Popis výsledku anglicky
Introduction: Diagnostic whole-body scintigraphy with 131I (dxWBS) in patients with differentiated thyroid cancers (DTC) is an important procedure to verify radioiodine avidity of the DTC tissue before planning 131I therapy. Guidelines of the scientific societies (EANM, SNMMI, DGN) do not mention the exact time of dxWBS acquisition, 48 or 72 hours after 131I application are mostly recommended. The goal of our limited study was to assess which time interval after 131I application is the best for the detection of accumulating foci on dxWBSMetod: We assessed 16 patients both 48 and 72 hours after application of 185 MBq of 131I during postablation dxWBS check-up. Planar scintigrams were acquired for 10 minutes at 48 hours and for 20 minutes at 72 hours post application. Images were performed with the gamma camera using HEGP collimator. Comparison of early and late scintigrams was performed visually, by calculation of foci contrast (T-B/B) and signal to noise ratio (SNR), respectively. Wilcoxon pair test was used to compare T-B/B and SNR in both acquisition times.Results: Focal accumulation of 131I in the neck was detected in 10 patients; it was definitely evident only on late scintigrams in 4 patients. Average value of T-B/B increased from 0,219 on early to 0,592 on late scintigrams (p = 0,005); average value of SNR increased from 0,457 to 0,841 equally (p = 0,005).Conclusion: We believe that dxWBS performed 72 hours after injection of 131I is diagnostically more effective even if the acquisition time is significantly longer.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nukleární medicína
ISSN
1805-1146
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
10-14
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—