Inhomogeneity of Ultrasound Field During Sonication Experiments in Vitro and Its Influence on the Overall Amount of Ultrasound Energy Entering a Sonication Vessel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F24%3A73626851" target="_blank" >RIV/61989592:15110/24:73626851 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/9835" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/9835</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2024.2.02" target="_blank" >10.14311/CTJ.2024.2.02</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inhomogeneity of Ultrasound Field During Sonication Experiments in Vitro and Its Influence on the Overall Amount of Ultrasound Energy Entering a Sonication Vessel
Popis výsledku v původním jazyce
Current sonication experiments in vitro show immense variability in experimental set-ups and equipment used. Many factors such as presence of standing waves or position of sonicated sample in ultrasound field during the experiment affect ultrasound field parameters the sonicated samples actually experience. The main goal of this work was to quantify influence of position of sonicated sample on maximum acoustic intensity and overall amount of ultrasound energy entering sonication vessel when placed at different distances from ultrasound transducer.
Název v anglickém jazyce
Inhomogeneity of Ultrasound Field During Sonication Experiments in Vitro and Its Influence on the Overall Amount of Ultrasound Energy Entering a Sonication Vessel
Popis výsledku anglicky
Current sonication experiments in vitro show immense variability in experimental set-ups and equipment used. Many factors such as presence of standing waves or position of sonicated sample in ultrasound field during the experiment affect ultrasound field parameters the sonicated samples actually experience. The main goal of this work was to quantify influence of position of sonicated sample on maximum acoustic intensity and overall amount of ultrasound energy entering sonication vessel when placed at different distances from ultrasound transducer.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Návaznosti výsledku
Projekt
<a href="/cs/project/NU21-09-00357" target="_blank" >NU21-09-00357: Výhody fotodynamické a sonodynamické terapie u multiresistentních mikroorganismů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lekar a Technika
ISSN
0301-5491
e-ISSN
2336-5552
Svazek periodika
54
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
43-47
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85210852220