Delirium screening instruments administered by nurses for hospitalized patients – literature review
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15120%2F20%3A73602462" target="_blank" >RIV/61989592:15120/20:73602462 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/19:A200230B RIV/61989592:15120/19:73607234
Výsledek na webu
<a href="https://cejnm.osu.cz/artkey/cjn-201904-0007_delirium-screening-instruments-administered-by-nurses-for-hospitalized-patients-literature-review.php" target="_blank" >https://cejnm.osu.cz/artkey/cjn-201904-0007_delirium-screening-instruments-administered-by-nurses-for-hospitalized-patients-literature-review.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15452/CEJNM.2019.10.0028" target="_blank" >10.15452/CEJNM.2019.10.0028</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Delirium screening instruments administered by nurses for hospitalized patients – literature review
Popis výsledku v původním jazyce
Aim: The aim of the paper was to create a literature review of valid and reliable delirium screening instruments administered by nurses for hospitalized patients. Design: Literature review. Methods: An advanced search of three licensed electronic databases (EBSCO, MEDLINE, PROQUEST) was selected. Twenty-one research studies complied with the inclusion criteria. Results: The predictive validity of ten delirium screening measuring tools were studied. The best predictive validity was found in the Nursing Delirium Screening Scale (Nu-DESC), with sensitivity values ranging from 32% to 100%, and specificity from 83% to 100%, with highest value for reliability of 0.94. The Delirium Observation Screening Scale (DOS) came second, with sensitivity from 25% to 97%, and specificity from 89% to 98.4%, with highest value for reliability of 0.77. The 4AT tool had sensitivity values from 83.3% to 90%, and specificity from 84% to 86.3%, with highest value for reliability of 0.99. Conclusion: The best screening tool for evaluating delirium by nurses was the Nu-DESC, followed by the DOS, and the 4AT. We recommend testing the predictive validity and reliability of selected screening tools administered by nurses in conditions of Czech clinical practice
Název v anglickém jazyce
Delirium screening instruments administered by nurses for hospitalized patients – literature review
Popis výsledku anglicky
Aim: The aim of the paper was to create a literature review of valid and reliable delirium screening instruments administered by nurses for hospitalized patients. Design: Literature review. Methods: An advanced search of three licensed electronic databases (EBSCO, MEDLINE, PROQUEST) was selected. Twenty-one research studies complied with the inclusion criteria. Results: The predictive validity of ten delirium screening measuring tools were studied. The best predictive validity was found in the Nursing Delirium Screening Scale (Nu-DESC), with sensitivity values ranging from 32% to 100%, and specificity from 83% to 100%, with highest value for reliability of 0.94. The Delirium Observation Screening Scale (DOS) came second, with sensitivity from 25% to 97%, and specificity from 89% to 98.4%, with highest value for reliability of 0.77. The 4AT tool had sensitivity values from 83.3% to 90%, and specificity from 84% to 86.3%, with highest value for reliability of 0.99. Conclusion: The best screening tool for evaluating delirium by nurses was the Nu-DESC, followed by the DOS, and the 4AT. We recommend testing the predictive validity and reliability of selected screening tools administered by nurses in conditions of Czech clinical practice
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30307 - Nursing
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Nursing and Midwifery
ISSN
2336-3517
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
1167-1178
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85075974121