Virtuální Mössbauerův spektrometr v PXI modulárním systému
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F05%3A00002213" target="_blank" >RIV/61989592:15310/05:00002213 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Virtual Mössbauer Spectrometer in the PXI Modular System
Popis výsledku v původním jazyce
A virtual instrumentation programming methodhas been used for building a computer-based Mössbauerspectrometer. Data acquisition is realized via two PXI orPCI commercially available modules, the digital oscilloscopeNI 5102 and the function generator NI 5401 (NationalInstruments), which are supported by relevant softwaredrivers. Virtual Mössbauer spectrometer is implemented bythe graphical programming language LabVIEW 7 Express.The RTSI bus is used for a synchronization of theregistration of gamma ray photons with a relative velocity ofthe motion between the radioactive source and the sample.The amplitude selection of the impulses from the detectoroutput is carried out by an assistance of the Waveform PeakDetection.vi function. The sampling rate of the detectoroutput signal and frequency of the velocity signal determinethe number of registration channels of the measuredMössbauer spectrum.
Název v anglickém jazyce
Virtual Mössbauer Spectrometer in the PXI Modular System
Popis výsledku anglicky
A virtual instrumentation programming methodhas been used for building a computer-based Mössbauerspectrometer. Data acquisition is realized via two PXI orPCI commercially available modules, the digital oscilloscopeNI 5102 and the function generator NI 5401 (NationalInstruments), which are supported by relevant softwaredrivers. Virtual Mössbauer spectrometer is implemented bythe graphical programming language LabVIEW 7 Express.The RTSI bus is used for a synchronization of theregistration of gamma ray photons with a relative velocity ofthe motion between the radioactive source and the sample.The amplitude selection of the impulses from the detectoroutput is carried out by an assistance of the Waveform PeakDetection.vi function. The sampling rate of the detectoroutput signal and frequency of the velocity signal determinethe number of registration channels of the measuredMössbauer spectrum.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0512" target="_blank" >1M0512: Centrrum výzkumu práškových nanomateriálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Kassel
Název nakladatele resp. objednatele
Kassel University Press
Verze
—
Identifikační číslo nosiče
—