Mossbauerovský spektrometr s rezonančním detektorem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F06%3A00002719" target="_blank" >RIV/61989592:15310/06:00002719 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/06:00003311
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mossbauer spectrometer with resonant detector
Popis výsledku v původním jazyce
A Mossbauer spectrometer with a collective synchronous motion of the radioactive source and resonant detector has been built. The new special transducer with four drive coils and one velocity pickup coil has been developed. The drive coils are distributed over a perimeter of the moving frame, which connects the source and resonant detector. This configuration ensures an effective suppression of any mechanical vibrations and excitations in the moving frame. The polyamide fibers serve as suspension brackets, barium ferrite magnets are used. The mechanical construction of the transducer allows the use of various cryostats and furnaces, because the sample is immovable. The spectrometer developed provides an effective application of resonant detectors in awide range of absorber temperatures.
Název v anglickém jazyce
Mossbauer spectrometer with resonant detector
Popis výsledku anglicky
A Mossbauer spectrometer with a collective synchronous motion of the radioactive source and resonant detector has been built. The new special transducer with four drive coils and one velocity pickup coil has been developed. The drive coils are distributed over a perimeter of the moving frame, which connects the source and resonant detector. This configuration ensures an effective suppression of any mechanical vibrations and excitations in the moving frame. The polyamide fibers serve as suspension brackets, barium ferrite magnets are used. The mechanical construction of the transducer allows the use of various cryostats and furnaces, because the sample is immovable. The spectrometer developed provides an effective application of resonant detectors in awide range of absorber temperatures.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0512" target="_blank" >1M0512: Centrrum výzkumu práškových nanomateriálů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research
ISSN
0168-583X
e-ISSN
—
Svazek periodika
243
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
241-246
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—