The application of Miniplex primer sets in the analysis of degraded DNA from human skeletal remains
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F06%3A73537340" target="_blank" >RIV/61989592:15310/06:73537340 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/epdf/10.1111/j.1556-4029.2006.00077.x" target="_blank" >https://onlinelibrary.wiley.com/doi/epdf/10.1111/j.1556-4029.2006.00077.x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/j.1556-4029.2006.00077.x" target="_blank" >10.1111/j.1556-4029.2006.00077.x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The application of Miniplex primer sets in the analysis of degraded DNA from human skeletal remains
Popis výsledku v původním jazyce
New set of multiplexed PCR primers has been applied to the analysis of human skeletal remains to determine their efficacy in analyzing degraded DNA. These primer sets, known as Miniplexes, produce shorter amplicons (50-280 base pairs (bp)) than standard short tandem repeat (STR) kits, but still utilize the 13 CODIS STR loci, providing results that are searchable on national DNA databases. In this study, a set of 31 different human remains were exposed to a variety of environmental conditions, extracted, and amplified with commercial and Miniplex DNA typing kits. The amplification efficiency of the Miniplex sets was then compared with the Promega PowerPlex(T) 16 system. Sixty-four percent of the samples generated full profiles when amplified with the Miniplexes, while only 16% of the samples generated full profiles with the Powerplex((R)) 16 kit. Complete profiles were obtained for 11 of the 12 Miniplex loci with amplicon sizes less than 200 bp. These data suggest smaller PCR amplicons may provide a useful alternative to mitochondrial DNA for anthropological and forensic analysis of degraded DNA from human skeletal remains.
Název v anglickém jazyce
The application of Miniplex primer sets in the analysis of degraded DNA from human skeletal remains
Popis výsledku anglicky
New set of multiplexed PCR primers has been applied to the analysis of human skeletal remains to determine their efficacy in analyzing degraded DNA. These primer sets, known as Miniplexes, produce shorter amplicons (50-280 base pairs (bp)) than standard short tandem repeat (STR) kits, but still utilize the 13 CODIS STR loci, providing results that are searchable on national DNA databases. In this study, a set of 31 different human remains were exposed to a variety of environmental conditions, extracted, and amplified with commercial and Miniplex DNA typing kits. The amplification efficiency of the Miniplex sets was then compared with the Promega PowerPlex(T) 16 system. Sixty-four percent of the samples generated full profiles when amplified with the Miniplexes, while only 16% of the samples generated full profiles with the Powerplex((R)) 16 kit. Complete profiles were obtained for 11 of the 12 Miniplex loci with amplicon sizes less than 200 bp. These data suggest smaller PCR amplicons may provide a useful alternative to mitochondrial DNA for anthropological and forensic analysis of degraded DNA from human skeletal remains.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10609 - Biochemical research methods
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Forensic Sciences
ISSN
0022-1198
e-ISSN
—
Svazek periodika
51
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
351-356
Kód UT WoS článku
000235841900018
EID výsledku v databázi Scopus
2-s2.0-33644925270