Kapilární elektroforéza jako ověřovací nástroj pro imunochemický screening drog
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F07%3A00004826" target="_blank" >RIV/61989592:15310/07:00004826 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary electrophoresis as a verification tool for immunochemical drug screening
Popis výsledku v původním jazyce
Background: The aim of this work was to develop a simple capillary electrophoretic method as the verifi cation and confi rmation tool in the screening analysis for amphetamines, opiates, benzodiazepines and cocaine and their metabolites for toxicologicalapplications. Methods: 50 mM phosphate Tris pH 2.0 with 30 % (v/v) of methanol was used as a background electrolyte that enabled fast separation of drugs and their metabolites in saliva and urine. Verifi cation of the data from the electrophoretic method was done by High Performance Thin Layer Chromatography (HPTLC) and the immunochemical screening test QuikScreen. Results: The experimental conditions of the Capillary Electrophoresis (CE) were partially optimized (mainly the infl uence of concentrationand types of additives, e.g. cyclodextrines, organic solvents) and validated; the method was used for analysing samples from drug abusers. Conclusions: The non-instrumental, immunoassay tests could only confi rm qualitative addictions an
Název v anglickém jazyce
Capillary electrophoresis as a verification tool for immunochemical drug screening
Popis výsledku anglicky
Background: The aim of this work was to develop a simple capillary electrophoretic method as the verifi cation and confi rmation tool in the screening analysis for amphetamines, opiates, benzodiazepines and cocaine and their metabolites for toxicologicalapplications. Methods: 50 mM phosphate Tris pH 2.0 with 30 % (v/v) of methanol was used as a background electrolyte that enabled fast separation of drugs and their metabolites in saliva and urine. Verifi cation of the data from the electrophoretic method was done by High Performance Thin Layer Chromatography (HPTLC) and the immunochemical screening test QuikScreen. Results: The experimental conditions of the Capillary Electrophoresis (CE) were partially optimized (mainly the infl uence of concentrationand types of additives, e.g. cyclodextrines, organic solvents) and validated; the method was used for analysing samples from drug abusers. Conclusions: The non-instrumental, immunoassay tests could only confi rm qualitative addictions an
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
151
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
31-36
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—