Měření tvaru ultratenkých zrcadel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F07%3A00007700" target="_blank" >RIV/61989592:15310/07:00007700 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Shape measuring of ultralight mirrors
Popis výsledku v původním jazyce
The theory, optical, mechanical and software design for a special Hartmann wavefront analyzer is presented. This method is applied for the non-contact method of concave mirrors shape measurements. The Joint Laboratory of Optics produces segmented mirrorsfor the Pierre Auger observatory fluorescent detector [1] and we use this method as the objective measurement of this spherical mirror segments. These segments are unique because they are light and ultra-thin. The production of mirrors is based on standard operations commonly used in the optical industry (cutting, drilling, milling, grinding and polishing), with the difference that they are extremely thin. This fact can cause segment shape instability in the production process. This method objectivelydefines the shape and specifies the difference of the segment shape from an ideal surface in micrometer accuracy.
Název v anglickém jazyce
Shape measuring of ultralight mirrors
Popis výsledku anglicky
The theory, optical, mechanical and software design for a special Hartmann wavefront analyzer is presented. This method is applied for the non-contact method of concave mirrors shape measurements. The Joint Laboratory of Optics produces segmented mirrorsfor the Pierre Auger observatory fluorescent detector [1] and we use this method as the objective measurement of this spherical mirror segments. These segments are unique because they are light and ultra-thin. The production of mirrors is based on standard operations commonly used in the optical industry (cutting, drilling, milling, grinding and polishing), with the difference that they are extremely thin. This fact can cause segment shape instability in the production process. This method objectivelydefines the shape and specifies the difference of the segment shape from an ideal surface in micrometer accuracy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M06002" target="_blank" >1M06002: Optické struktury, detekční systémy a související technologie pro nízkofotonové aplikace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Optické struktury, detekční systémy a související technologie pro nízkofotonové aplikace
ISBN
978-80-244-1844-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Univerzita Palackého
Místo vydání
Olomouc
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—