Charakterizace DESI-FTICR hmotnostní spektrometrie - od ECD k přesné hmotnostní analýze
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F08%3A00005431" target="_blank" >RIV/61989592:15310/08:00005431 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388971:_____/08:00313035
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of DESI-FTICR mass spectrometry - from ECD to accurate mass tissue analysis
Popis výsledku v původním jazyce
Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance ITTICR) mass spectrometer is described. Desorption electrospray technique is capable of the direct investigation of natural sampleswithout any need for sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex owing to the lack of preseparation or cleanup, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. A three-dimensional linear stage was used to accommodatesamples, while another 3D linear stage equipped with rotating stage was used as a spray mount. A modified electrosonic sprayer was used as a primary electrospray device. DESI-FTICR setup was characterized with regard to geometrical, elec
Název v anglickém jazyce
Characterization of DESI-FTICR mass spectrometry - from ECD to accurate mass tissue analysis
Popis výsledku anglicky
Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance ITTICR) mass spectrometer is described. Desorption electrospray technique is capable of the direct investigation of natural sampleswithout any need for sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex owing to the lack of preseparation or cleanup, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. A three-dimensional linear stage was used to accommodatesamples, while another 3D linear stage equipped with rotating stage was used as a spray mount. A modified electrosonic sprayer was used as a primary electrospray device. DESI-FTICR setup was characterized with regard to geometrical, elec
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Mass Spectrometry
ISSN
1076-5174
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—