Nanoelectrospray versus electrospray in chiral analysis by the kinetic method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F09%3A00010408" target="_blank" >RIV/61989592:15310/09:00010408 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nanoelectrospray versus electrospray in chiral analysis by the kinetic method
Popis výsledku v původním jazyce
Electrospray ionization generates trimeric diastereoisomeric clusters as the first important step in chiral analysis by mass spectrometry using the Cooks' kinetic method. Cu2+ and L-tryptophan were used as a central metal and as a chiral reference ligand, respectively. The comparison of electrospray and nanoelectrospray showed that although the electrospray system was generally more robust, the application of nanoelectrospray was essential for performing successful analysis in some cases, especially forreal samples. Basically, no significant differences between the ion sources were observed for model samples of analytes (isoleucine, ephedrine, phenylalanine) without interfering matrix. On the other hand, model samples containing sodium chloride and abuffer containing a real sample (drug formulation Mucoseptonex E in which D-ephedrine is the active substance) could not be analyzed using ESI, whereas nano-ESI gave satisfactory results. An explanation is based on the differences of ioni
Název v anglickém jazyce
Nanoelectrospray versus electrospray in chiral analysis by the kinetic method
Popis výsledku anglicky
Electrospray ionization generates trimeric diastereoisomeric clusters as the first important step in chiral analysis by mass spectrometry using the Cooks' kinetic method. Cu2+ and L-tryptophan were used as a central metal and as a chiral reference ligand, respectively. The comparison of electrospray and nanoelectrospray showed that although the electrospray system was generally more robust, the application of nanoelectrospray was essential for performing successful analysis in some cases, especially forreal samples. Basically, no significant differences between the ion sources were observed for model samples of analytes (isoleucine, ephedrine, phenylalanine) without interfering matrix. On the other hand, model samples containing sodium chloride and abuffer containing a real sample (drug formulation Mucoseptonex E in which D-ephedrine is the active substance) could not be analyzed using ESI, whereas nano-ESI gave satisfactory results. An explanation is based on the differences of ioni
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F07%2F0765" target="_blank" >GA203/07/0765: Analýza izomerů hmotnostní spektrometrií a kinetickou metodou</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communications
ISSN
0010-0765
e-ISSN
—
Svazek periodika
74
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—