CONTROLLED BAND DISPERSION FOR QUANTITATIVE BINDING DETERMINATION AND ANALYSIS WITH ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F10%3A10215676" target="_blank" >RIV/61989592:15310/10:10215676 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CONTROLLED BAND DISPERSION FOR QUANTITATIVE BINDING DETERMINATION AND ANALYSIS WITH ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
Popis výsledku v původním jazyce
This review discusses recent emerging techniques that have been used to couple flow-injection analysis (FIA) and electrospray ionization-mass spectrometry (ESI-MS) for the quantitation of noncovalent binding interactions. Focus is placed predominantly ontwo such methods. Diffusion-based measurements, developed by Konermann and co-workers, uses controlled-band dispersion prior to ESI-MS to determine diffusion constants and binding constants based on the temporal variation of ligand signal measured in the mass spectrum (an indirect technique). Dynamic titration, developed by Schug and co-workers, is a direct method, where a temporal compositional gradient of a guest molecule is induced in the presence of host in solution to monitor the concentration dependence of complex formation as a function of observed complex ion abundance after ESI-MS. Further discussion places these techniques in the context of a variety of other direct and indirect ESI-MS-based binding determination methods.
Název v anglickém jazyce
CONTROLLED BAND DISPERSION FOR QUANTITATIVE BINDING DETERMINATION AND ANALYSIS WITH ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
Popis výsledku anglicky
This review discusses recent emerging techniques that have been used to couple flow-injection analysis (FIA) and electrospray ionization-mass spectrometry (ESI-MS) for the quantitation of noncovalent binding interactions. Focus is placed predominantly ontwo such methods. Diffusion-based measurements, developed by Konermann and co-workers, uses controlled-band dispersion prior to ESI-MS to determine diffusion constants and binding constants based on the temporal variation of ligand signal measured in the mass spectrum (an indirect technique). Dynamic titration, developed by Schug and co-workers, is a direct method, where a temporal compositional gradient of a guest molecule is induced in the presence of host in solution to monitor the concentration dependence of complex formation as a function of observed complex ion abundance after ESI-MS. Further discussion places these techniques in the context of a variety of other direct and indirect ESI-MS-based binding determination methods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Mass Spectrometry Reviews
ISSN
0277-7037
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
24
Strana od-do
—
Kód UT WoS článku
000281724300006
EID výsledku v databázi Scopus
—