Self-calibration for self-consistent tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33140137" target="_blank" >RIV/61989592:15310/12:33140137 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1367-2630/14/9/095001" target="_blank" >http://dx.doi.org/10.1088/1367-2630/14/9/095001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1367-2630/14/9/095001" target="_blank" >10.1088/1367-2630/14/9/095001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Self-calibration for self-consistent tomography
Popis výsledku v původním jazyce
Self-calibrating states are introduced as quantum resources for the simultaneous reconstruction of a quantum state and measurement device. Simple criteria for a state being self-calibrating are formulated. Theory applies to realistic state estimation scenarios, where the detection model is nonlinear in unknown parameters of the measuring device. Examples discussed include time multiplexed detection with on/off detectors and quantum homodyne tomography. The thermally noised single-photon states and Gaussian states are self-calibrating for these schemes. For homodyne tomography, statistical tests applied to raw measured data are sufficient for judging whether or not the signal state is self-calibrating without any a priori information.
Název v anglickém jazyce
Self-calibration for self-consistent tomography
Popis výsledku anglicky
Self-calibrating states are introduced as quantum resources for the simultaneous reconstruction of a quantum state and measurement device. Simple criteria for a state being self-calibrating are formulated. Theory applies to realistic state estimation scenarios, where the detection model is nonlinear in unknown parameters of the measuring device. Examples discussed include time multiplexed detection with on/off detectors and quantum homodyne tomography. The thermally noised single-photon states and Gaussian states are self-calibrating for these schemes. For homodyne tomography, statistical tests applied to raw measured data are sufficient for judging whether or not the signal state is self-calibrating without any a priori information.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F364" target="_blank" >FR-TI1/364: *Multispektrální systémy pro syntézu obrazu viditelné a termovizní části spektra</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
New Journal of Physics
ISSN
1367-2630
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
"095001-1"-"095001-10"
Kód UT WoS článku
000308744600001
EID výsledku v databázi Scopus
—