Analysis of microorganisms by capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142144" target="_blank" >RIV/61989592:15310/12:33142144 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.trac.2011.07.013" target="_blank" >http://dx.doi.org/10.1016/j.trac.2011.07.013</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.trac.2011.07.013" target="_blank" >10.1016/j.trac.2011.07.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of microorganisms by capillary electrophoresis
Popis výsledku v původním jazyce
Microorganisms are well known for their positive, as well as negative, effects on health, which mean that there is a great need for methods of discovery, identification and determination of microorganisms. In the past decade, capillary electrophoresis (CE) began to be an interesting tool for analysis of microorganisms, interestingly sometimes with similar dimensions for the separation capillary and the microorganisms. This review focuses on the use of CE in the analysis of microorganisms. First, it looks at the origin of microbial surface charge and then describes key points in the analysis of microbes by capillary zone electrophoresis [first approaches using poly(ethylene oxide), covalent modification of the inner capillary wall, reversed electroosmotic flow, advances in detection, and on-line preconcentration] and capillary isoelectric focusing.
Název v anglickém jazyce
Analysis of microorganisms by capillary electrophoresis
Popis výsledku anglicky
Microorganisms are well known for their positive, as well as negative, effects on health, which mean that there is a great need for methods of discovery, identification and determination of microorganisms. In the past decade, capillary electrophoresis (CE) began to be an interesting tool for analysis of microorganisms, interestingly sometimes with similar dimensions for the separation capillary and the microorganisms. This review focuses on the use of CE in the analysis of microorganisms. First, it looks at the origin of microbial surface charge and then describes key points in the analysis of microbes by capillary zone electrophoresis [first approaches using poly(ethylene oxide), covalent modification of the inner capillary wall, reversed electroosmotic flow, advances in detection, and on-line preconcentration] and capillary isoelectric focusing.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0058" target="_blank" >ED2.1.00/03.0058: Regionální centrum pokročilých technologií a materiálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Trends in Analytical Chemistry
ISSN
0165-9936
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
14
Strana od-do
9-22
Kód UT WoS článku
000299973800011
EID výsledku v databázi Scopus
—