Analogue and digital analysis of the effects of some parameters in determination of the best experimental energy resolution.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F14%3A33151654" target="_blank" >RIV/61989592:15310/14:33151654 - isvavai.cz</a>
Výsledek na webu
<a href="http://journals.tubitak.gov.tr/physics/issues/fiz-14-38-2/fiz-38-2-6-1401-10.pdf" target="_blank" >http://journals.tubitak.gov.tr/physics/issues/fiz-14-38-2/fiz-38-2-6-1401-10.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3906/fiz-1401-10" target="_blank" >10.3906/fiz-1401-10</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analogue and digital analysis of the effects of some parameters in determination of the best experimental energy resolution.
Popis výsledku v původním jazyce
The gamma-ray energy spectrum of 137 Cs was obtained according to different parameters such as preamplifer capacitance, the amplifer's coarse gain level, power supply voltage for the detector, and source-to-detector distance. This investigation was performed with both analogue and digital methods. In order to examine the effects of these parameters on energy resolution, a NaI(Tl) inorganic scintillation detector was used. In addition, the gamma energy spectrum of the radioisotope was obtained by means of FLUKA, which is one of the Monte Carlo simulation programmes. Energy resolution of the detector by these 3 methods was calculated. These resolution values were compared with each other.
Název v anglickém jazyce
Analogue and digital analysis of the effects of some parameters in determination of the best experimental energy resolution.
Popis výsledku anglicky
The gamma-ray energy spectrum of 137 Cs was obtained according to different parameters such as preamplifer capacitance, the amplifer's coarse gain level, power supply voltage for the detector, and source-to-detector distance. This investigation was performed with both analogue and digital methods. In order to examine the effects of these parameters on energy resolution, a NaI(Tl) inorganic scintillation detector was used. In addition, the gamma energy spectrum of the radioisotope was obtained by means of FLUKA, which is one of the Monte Carlo simulation programmes. Energy resolution of the detector by these 3 methods was calculated. These resolution values were compared with each other.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Turkish Journal of Physics
ISSN
1300-0101
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
TR - Turecká republika
Počet stran výsledku
10
Strana od-do
203-213
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—