Influence of High Energy Heavy Ions on Magnetic Susceptibility of Soft Magnetic Metallic Glasses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F14%3A33151756" target="_blank" >RIV/61989592:15310/14:33151756 - isvavai.cz</a>
Výsledek na webu
<a href="http://przyrbwn.icm.edu.pl/APP/PDF/126/a126z1p023.pdf" target="_blank" >http://przyrbwn.icm.edu.pl/APP/PDF/126/a126z1p023.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.12693/APhysPolA.126.54" target="_blank" >10.12693/APhysPolA.126.54</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of High Energy Heavy Ions on Magnetic Susceptibility of Soft Magnetic Metallic Glasses
Popis výsledku v původním jazyce
This contribution presents experimental data concerning the inuence of fast heavy ions on magnetic susceptibility of VITROVACR 6025 and VITROPERMR 800 metallic glasses. Samples of magnetic ribbons were irradiated with Au, and Ta ions at 11.1 MeV/A (energy per nucleon), and U ions at 5.9 MeV/A. The irradiation uences varied from 5 1010 up to 1:2 1013 ions/cm2. Relative change of the samples' magnetic susceptibility after and before irradiation was measured and evaluated as a function of the irradiation uence. Measurements were done with a commercial Kappa-bridge device. We observed that VITROPERMR showed less change of magnetic susceptibility in comparison with VITROVACR and this change occurred at higher uences. This indicates higher radiation hardnessof VITROPERMR compared with VITROVACR against high-energy heavy ions. In addition,heavier ions caused larger change of magnetic susceptibility than the lighter ones and the eect could be roughly scaled with the level of electronic stoppi
Název v anglickém jazyce
Influence of High Energy Heavy Ions on Magnetic Susceptibility of Soft Magnetic Metallic Glasses
Popis výsledku anglicky
This contribution presents experimental data concerning the inuence of fast heavy ions on magnetic susceptibility of VITROVACR 6025 and VITROPERMR 800 metallic glasses. Samples of magnetic ribbons were irradiated with Au, and Ta ions at 11.1 MeV/A (energy per nucleon), and U ions at 5.9 MeV/A. The irradiation uences varied from 5 1010 up to 1:2 1013 ions/cm2. Relative change of the samples' magnetic susceptibility after and before irradiation was measured and evaluated as a function of the irradiation uence. Measurements were done with a commercial Kappa-bridge device. We observed that VITROPERMR showed less change of magnetic susceptibility in comparison with VITROVACR and this change occurred at higher uences. This indicates higher radiation hardnessof VITROPERMR compared with VITROVACR against high-energy heavy ions. In addition,heavier ions caused larger change of magnetic susceptibility than the lighter ones and the eect could be roughly scaled with the level of electronic stoppi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Physica Polonica A
ISSN
0587-4246
e-ISSN
—
Svazek periodika
126
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
2
Strana od-do
54-55
Kód UT WoS článku
000339833100024