Popis výsledku v původním jazyce
A better understanding of environmental factors influencing human health will benefit from the availability of fast and reliable methods allowing the quasi simultaneous measurement of a panel of endpoints in cell exposure studies. Automated cell-counting methods are basic for this purpose if comparability with traditional manual cell counting procedure is documented. In the present paper, both dead and viable cells of human lung adenocarcinoma epithelial cell line (A549) and human bronchial epithelial cell line (16HBE 14o-) at various cell densities ranging from 50 000 to 400 000 cells/ml, are counted by both Trypan blue dye exclusion staining counted with a hemo-cytometer and a handheld automated cell counter based on the Coulter principle (Scepter 2.0, Millipore). Correlation indexes higher than 0.998 have been obtained using both cell counting protocols in all cases, thus confirming the reliable use of automated cell counters whenever fast, easy to use, precise cell counting is a requisite.
Název v anglickém jazyce
Fast Cell Counting - The Better Cell Counting?
Popis výsledku anglicky
A better understanding of environmental factors influencing human health will benefit from the availability of fast and reliable methods allowing the quasi simultaneous measurement of a panel of endpoints in cell exposure studies. Automated cell-counting methods are basic for this purpose if comparability with traditional manual cell counting procedure is documented. In the present paper, both dead and viable cells of human lung adenocarcinoma epithelial cell line (A549) and human bronchial epithelial cell line (16HBE 14o-) at various cell densities ranging from 50 000 to 400 000 cells/ml, are counted by both Trypan blue dye exclusion staining counted with a hemo-cytometer and a handheld automated cell counter based on the Coulter principle (Scepter 2.0, Millipore). Correlation indexes higher than 0.998 have been obtained using both cell counting protocols in all cases, thus confirming the reliable use of automated cell counters whenever fast, easy to use, precise cell counting is a requisite.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0004" target="_blank" >EE2.3.30.0004: Podpora vytváření excelentních výzkumných týmů a intersektorální mobility na Univerzitě Palackého v Olomouci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fresenius Environmental Bulletin
ISSN
1018-4619
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
3054-3058
Kód UT WoS článku
000348744700015
EID výsledku v databázi Scopus
—