Entanglement-Enhanced Radio-Frequency Field Detection and Waveform Sensing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F17%3A73581356" target="_blank" >RIV/61989592:15310/17:73581356 - isvavai.cz</a>
Výsledek na webu
<a href="https://journals.aps.org/prl/pdf/10.1103/PhysRevLett.119.043603" target="_blank" >https://journals.aps.org/prl/pdf/10.1103/PhysRevLett.119.043603</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1103/PhysRevLett.119.043603" target="_blank" >10.1103/PhysRevLett.119.043603</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Entanglement-Enhanced Radio-Frequency Field Detection and Waveform Sensing
Popis výsledku v původním jazyce
We demonstrate a new technique for detecting the amplitude of arbitrarily chosen components of radio-frequency waveforms based on stroboscopic backaction evading measurements. We combine quantum nondemolition measurements and stroboscopic probing to detect waveform components with magnetic sensitivity beyond the standard quantum limit. Using an ensemble of 1.5 x 10(6) cold rubidium atoms, we demonstrate entanglement-enhanced sensing of sinusoidal and linearly chirped waveforms, with 1.0(2) and 0.8(3) dB metrologically relevant noise reduction, respectively. We achieve volume-adjusted sensitivity of delta B root V approximate to 3.96 ft root cm(2)/Hz, comparable to the best rf magnetometers.
Název v anglickém jazyce
Entanglement-Enhanced Radio-Frequency Field Detection and Waveform Sensing
Popis výsledku anglicky
We demonstrate a new technique for detecting the amplitude of arbitrarily chosen components of radio-frequency waveforms based on stroboscopic backaction evading measurements. We combine quantum nondemolition measurements and stroboscopic probing to detect waveform components with magnetic sensitivity beyond the standard quantum limit. Using an ensemble of 1.5 x 10(6) cold rubidium atoms, we demonstrate entanglement-enhanced sensing of sinusoidal and linearly chirped waveforms, with 1.0(2) and 0.8(3) dB metrologically relevant noise reduction, respectively. We achieve volume-adjusted sensitivity of delta B root V approximate to 3.96 ft root cm(2)/Hz, comparable to the best rf magnetometers.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physical Review Letters
ISSN
0031-9007
e-ISSN
—
Svazek periodika
119
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
"043603-1"-"043603-5"
Kód UT WoS článku
000406328300007
EID výsledku v databázi Scopus
—