Effects of coherence on temporal resolution
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F21%3A73607370" target="_blank" >RIV/61989592:15310/21:73607370 - isvavai.cz</a>
Výsledek na webu
<a href="https://journals.aps.org/prresearch/pdf/10.1103/PhysRevResearch.3.033082" target="_blank" >https://journals.aps.org/prresearch/pdf/10.1103/PhysRevResearch.3.033082</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1103/PhysRevResearch.3.033082" target="_blank" >10.1103/PhysRevResearch.3.033082</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of coherence on temporal resolution
Popis výsledku v původním jazyce
Measuring small separations between two optical sources, either in space or in time, constitutes an important metrological challenge as standard intensity-only measurements fail for vanishing separations. Contrarily, it has been established that appropriate coherent mode projections can appraise arbitrarily small separations with quantum-limited precision. However, the question of whether the optical coherence brings any metrological advantage to mode projections is still a point of debate. Here, we elucidate this problem by experimentally investigating the effect of varying coherence on estimating the temporal separation between two single-photon pulses. We show that, for an accurate interpretation, special attention must be paid to properly normalize the quantum Fisher information to account for the strength of the signal.
Název v anglickém jazyce
Effects of coherence on temporal resolution
Popis výsledku anglicky
Measuring small separations between two optical sources, either in space or in time, constitutes an important metrological challenge as standard intensity-only measurements fail for vanishing separations. Contrarily, it has been established that appropriate coherent mode projections can appraise arbitrarily small separations with quantum-limited precision. However, the question of whether the optical coherence brings any metrological advantage to mode projections is still a point of debate. Here, we elucidate this problem by experimentally investigating the effect of varying coherence on estimating the temporal separation between two single-photon pulses. We show that, for an accurate interpretation, special attention must be paid to properly normalize the quantum Fisher information to account for the strength of the signal.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA18-04291S" target="_blank" >GA18-04291S: Fundamentální meze rozlišení v optické detekci a metrologii.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physical Review Research
ISSN
2643-1564
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
"033082-1"-"033082-7"
Kód UT WoS článku
000679366800003
EID výsledku v databázi Scopus
2-s2.0-85113948729