Self-assembling of PDMS microlens arrays through pyro-EHD for real-time 3D microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F24%3A73625323" target="_blank" >RIV/61989592:15310/24:73625323 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0143816624002185" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0143816624002185</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.optlaseng.2024.108239" target="_blank" >10.1016/j.optlaseng.2024.108239</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Self-assembling of PDMS microlens arrays through pyro-EHD for real-time 3D microscopy
Popis výsledku v původním jazyce
The electrohydrodynamic effect has been exploited for the fabrication of polymeric microlenses through different approaches. Here we show that microlens arrays obtained with the pyro-EHD self-assembling process exhibit high fill-factor and good level of homogeneity, thus allowing to integrate them in a lightfield microscope. Digital holographic microscopy is used to characterize the fabricated microlens array. Afterwards, a Fourier lightfield microscope is built by placing this microlens array at the Fourier plane of the objective. We demonstrate for the first time that the self-assembled PDMS microlens array is suitable for 3D imaging of microscopic samples, computationally reconstructing the volume of a thick fluorescent sample.
Název v anglickém jazyce
Self-assembling of PDMS microlens arrays through pyro-EHD for real-time 3D microscopy
Popis výsledku anglicky
The electrohydrodynamic effect has been exploited for the fabrication of polymeric microlenses through different approaches. Here we show that microlens arrays obtained with the pyro-EHD self-assembling process exhibit high fill-factor and good level of homogeneity, thus allowing to integrate them in a lightfield microscope. Digital holographic microscopy is used to characterize the fabricated microlens array. Afterwards, a Fourier lightfield microscope is built by placing this microlens array at the Fourier plane of the objective. We demonstrate for the first time that the self-assembled PDMS microlens array is suitable for 3D imaging of microscopic samples, computationally reconstructing the volume of a thick fluorescent sample.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
OPTICS AND LASERS IN ENGINEERING
ISSN
0143-8166
e-ISSN
1873-0302
Svazek periodika
178
Číslo periodika v rámci svazku
JUL
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
"108239-1"-"108239-8"
Kód UT WoS článku
001230978000001
EID výsledku v databázi Scopus
2-s2.0-85190442491