Analýza rozložení tlaků na kontaktu nohy a podložky při chůzi s transtibiální protézou
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F06%3A00002681" target="_blank" >RIV/61989592:15510/06:00002681 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The analysis of the gait pressure pattern at the interface between the foot and the ground in trans-tibial amputees [CD]
Popis výsledku v původním jazyce
Re-education in walking requires careful definition of all abnormalities in the patient's gait that differ from the standard pattern of muscle activity. These requirements do not apply only to the prosthetic limb, but in unilateral amputation also to thesound limb, which has to fulfil higher requirements in ensuring stability and propulsion. The aim of this study was to analyse the influence of various types (conventional; dynamic) of the prosthetic feet on the gait pressure pattern of unilateral trans-tibial amputees. The Footscan system (2m plate) was used for the gait analysis of 11 males (aged 46.1 +/- 12.0 years) with unilateral trans-tibial amputation. We did not detect any significant differences in loading of the sound limb when walking with various types of prosthetic foot, with the exception of early end of heel loading when walking with dynamic prosthesis. The COP trajectory in a conventional prosthetic foot is similar as in the data obtained for a sound limb.
Název v anglickém jazyce
The analysis of the gait pressure pattern at the interface between the foot and the ground in trans-tibial amputees [CD]
Popis výsledku anglicky
Re-education in walking requires careful definition of all abnormalities in the patient's gait that differ from the standard pattern of muscle activity. These requirements do not apply only to the prosthetic limb, but in unilateral amputation also to thesound limb, which has to fulfil higher requirements in ensuring stability and propulsion. The aim of this study was to analyse the influence of various types (conventional; dynamic) of the prosthetic feet on the gait pressure pattern of unilateral trans-tibial amputees. The Footscan system (2m plate) was used for the gait analysis of 11 males (aged 46.1 +/- 12.0 years) with unilateral trans-tibial amputation. We did not detect any significant differences in loading of the sound limb when walking with various types of prosthetic foot, with the exception of early end of heel loading when walking with dynamic prosthesis. The COP trajectory in a conventional prosthetic foot is similar as in the data obtained for a sound limb.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FI-IM2%2F076" target="_blank" >FI-IM2/076: Aplikace moderních materiálů a technologií při vývoji nové řady geriatrických protetických chodidel.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-214-3232-2
Místo vydání
Brno
Název nakladatele resp. objednatele
Vysoké učení technické
Verze
—
Identifikační číslo nosiče
—