Neinvazivní vyšetření funkce autonomního nervového systému s využitím systému VarCor PF7
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F06%3A00003443" target="_blank" >RIV/61989592:15510/06:00003443 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Non-invasive investigation of the function of the autonomic nervous system with the use of the VarCor PF7 System
Popis výsledku v původním jazyce
For non-invasive investigation of the function of the autonomic nervous system (ANS) the microcomputer telemetric system VarCor PF7 is designed, whose computer program includes algorithms for evaluation of heart rate variability (HRV) in both time and frequency domains. Evaluation of HRV in the time domain includes procedures for calculation of the statistical values of RR intervals and procedures for functional test controls, presented in the Ewings cardiovascular test batteries. Evaluation of HRV in the frequency domain includes the algorithm of the "short-term" spectral analysis of HRV (SAHRV) applied to the defined load situations: SUPINE - STANDING - SUPINE. The calculation of SAHRV parameters in the frequency bands VLF, LF and HF is performed using Fast Fourier Transformation (FFT). The high number of SAHRV parameters, together with their positive or negative age dependency, causes interpretation to be very difficult. Therefore the VarCor PF7 system includes procedures which have
Název v anglickém jazyce
Non-invasive investigation of the function of the autonomic nervous system with the use of the VarCor PF7 System
Popis výsledku anglicky
For non-invasive investigation of the function of the autonomic nervous system (ANS) the microcomputer telemetric system VarCor PF7 is designed, whose computer program includes algorithms for evaluation of heart rate variability (HRV) in both time and frequency domains. Evaluation of HRV in the time domain includes procedures for calculation of the statistical values of RR intervals and procedures for functional test controls, presented in the Ewings cardiovascular test batteries. Evaluation of HRV in the frequency domain includes the algorithm of the "short-term" spectral analysis of HRV (SAHRV) applied to the defined load situations: SUPINE - STANDING - SUPINE. The calculation of SAHRV parameters in the frequency bands VLF, LF and HF is performed using Fast Fourier Transformation (FFT). The high number of SAHRV parameters, together with their positive or negative age dependency, causes interpretation to be very difficult. Therefore the VarCor PF7 system includes procedures which have
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
5th international conference Movement and health - proceedings
ISBN
83-60691-05-3
ISSN
—
e-ISSN
—
Počet stran výsledku
637
Strana od-do
486-493
Název nakladatele
Opole University of Technology
Místo vydání
Opole
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—