Reliability of V sit-and-reach test used for flexibility self-assessment in females
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F13%3A33145401" target="_blank" >RIV/61989592:15510/13:33145401 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.gymnica.upol.cz/index.php/gymnica/article/view/360/228" target="_blank" >http://www.gymnica.upol.cz/index.php/gymnica/article/view/360/228</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reliability of V sit-and-reach test used for flexibility self-assessment in females
Popis výsledku v původním jazyce
BACKGROUND: The V sit-and-reach (VSR) test seems to be an appropriate instrument of self-assessment of hamstring and low-back flexibility for its ease of execution and the need for only a small amount of materials, space, and examination skill requirements. It is assumed that the specificity of self-assessment (in general) can be the cause of other sources of measurement error. OBJECTIVE: This study aimed to analyze reliability of VSR when used as an instrument of self-assessment of flexibility in adolescent females. METHODS: The sample comprised 43 students (female; age 21.2 +- 0.5 years) from Palacký University in Olomouc (Czech Republic). T-test (p { .05) and Pearson correlation coefficient was used to assess systematic bias and to determine intra-individual reliability of the flexibility test; the standard error of measurement (SEM) and Bland and Altman's 95% limits of agreement were used to assess absolute reliability of the flexibility test. RESULTS: The average intra-individual
Název v anglickém jazyce
Reliability of V sit-and-reach test used for flexibility self-assessment in females
Popis výsledku anglicky
BACKGROUND: The V sit-and-reach (VSR) test seems to be an appropriate instrument of self-assessment of hamstring and low-back flexibility for its ease of execution and the need for only a small amount of materials, space, and examination skill requirements. It is assumed that the specificity of self-assessment (in general) can be the cause of other sources of measurement error. OBJECTIVE: This study aimed to analyze reliability of VSR when used as an instrument of self-assessment of flexibility in adolescent females. METHODS: The sample comprised 43 students (female; age 21.2 +- 0.5 years) from Palacký University in Olomouc (Czech Republic). T-test (p { .05) and Pearson correlation coefficient was used to assess systematic bias and to determine intra-individual reliability of the flexibility test; the standard error of measurement (SEM) and Bland and Altman's 95% limits of agreement were used to assess absolute reliability of the flexibility test. RESULTS: The average intra-individual
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AK - Sport a aktivity volného času
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Palackianae Olomucensis. Gymnica
ISSN
1213-8312
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
35-39
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—