Reliability and validity of a basketball-specific fatigue protocol simulating match load
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F17%3A73583245" target="_blank" >RIV/61989592:15510/17:73583245 - isvavai.cz</a>
Výsledek na webu
<a href="https://gymnica.upol.cz/pdfs/gym/2017/02/06.pdf" target="_blank" >https://gymnica.upol.cz/pdfs/gym/2017/02/06.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/ag.2017.009" target="_blank" >10.5507/ag.2017.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reliability and validity of a basketball-specific fatigue protocol simulating match load
Popis výsledku v původním jazyce
Background: Research on the amount and type of fatigue caused by match load depends on protocols based on time- motion analysis of match performance in a given sport. The role of these protocols is to accurately simulate specific player match load, which is, contrary to a match, identical for all participants. Objective: The purpose of the study was to determine the reliability and validity using a basketball-specific fatigue protocol simulating player’s performance during a basketball match. Methods: The study involved a total of 25 male basketball players (age 17.4 ± 1.5 years; body height 185.1 ± 7.4 cm and body mass index 22.1 ± 0.3 kg ⋅ m–2) of U17 and U19 categories. The participants performed a specific basketball fatigue protocol twice during 14 days consisting of four periods separated by breaks as in a basketball match. Each period contained a stage with maximum intensity activities followed by a stage of medium intensity and low intensity. During the protocol, heart rate was recorded and time intervals of maximum, medium and low intensity were measured. Results: The relative reliability measurement pointed to high intra-individual stability of the results, when intraclass correlation coefficient varied from .71 to .92. The typical error of measurement showed that the players should be able to repeat the measurement with less than 1.31 s (0.82%) in total time, 0.17 s (2.73%) in sprint time, and 1.32% (1.19%) for percentage of heart rate. The values 1.68 (38.35%) of Sprint decrement showed very low repeatability. Conclusion: Measurements using a fatigue protocol showed high validity, reliability, and agree- ment of repeated measures.
Název v anglickém jazyce
Reliability and validity of a basketball-specific fatigue protocol simulating match load
Popis výsledku anglicky
Background: Research on the amount and type of fatigue caused by match load depends on protocols based on time- motion analysis of match performance in a given sport. The role of these protocols is to accurately simulate specific player match load, which is, contrary to a match, identical for all participants. Objective: The purpose of the study was to determine the reliability and validity using a basketball-specific fatigue protocol simulating player’s performance during a basketball match. Methods: The study involved a total of 25 male basketball players (age 17.4 ± 1.5 years; body height 185.1 ± 7.4 cm and body mass index 22.1 ± 0.3 kg ⋅ m–2) of U17 and U19 categories. The participants performed a specific basketball fatigue protocol twice during 14 days consisting of four periods separated by breaks as in a basketball match. Each period contained a stage with maximum intensity activities followed by a stage of medium intensity and low intensity. During the protocol, heart rate was recorded and time intervals of maximum, medium and low intensity were measured. Results: The relative reliability measurement pointed to high intra-individual stability of the results, when intraclass correlation coefficient varied from .71 to .92. The typical error of measurement showed that the players should be able to repeat the measurement with less than 1.31 s (0.82%) in total time, 0.17 s (2.73%) in sprint time, and 1.32% (1.19%) for percentage of heart rate. The values 1.68 (38.35%) of Sprint decrement showed very low repeatability. Conclusion: Measurements using a fatigue protocol showed high validity, reliability, and agree- ment of repeated measures.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Gymnica
ISSN
2336-4912
e-ISSN
—
Svazek periodika
47
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
92-98
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85022184250