Reliability of ankle–foot complex isokinetic strength assessment using the Isomed 2000 dynamometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F18%3A73587230" target="_blank" >RIV/61989592:15510/18:73587230 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.mdpi.com/1010-660X/54/3/43/htm" target="_blank" >http://www.mdpi.com/1010-660X/54/3/43/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/medicina54030043" target="_blank" >10.3390/medicina54030043</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reliability of ankle–foot complex isokinetic strength assessment using the Isomed 2000 dynamometer
Popis výsledku v původním jazyce
For quantifying muscle strength in clinical and research practice, establishing the reliability of measurements, specifically to the procedures used, is essential for credible findings. The objective was to establish the reliability of isokinetic measurement of ankle plantar and dorsal flexors (PF/DF) and invertors and evertors (INV/EV) on an IsoMed 2000 dynamometer. Twenty healthy subjects (10 males, 10 females, mean age: 23.1 ± 3.1 years) completed an isokinetic measurement session. The intraclass correlation coefficient (ICC) and standard error of measurement were assessed for peak torque and work of ankle PF/DF (concentric and eccentric) and INV/EV (concentric) for the preferred and nonpreferred limb. Standardized isokinetic measurements of reciprocal PF/DF and INV/EV muscle actions were associated with ICC ranging from 0.77 to 0.98 for the majority of observed parameters. The exception was work in the eccentric mode in the ankle DF and peak torque in the concentric mode in the ankle INV on the preferred limb, where ICC ranged from 0.64 to 0.71. The IsoMed 2000 isokinetic dynamometer can be reliably employed in future studies for reciprocal ankle PF/DF and INV/EV assessment in healthy adult subjects after implementation of a familiarization session.
Název v anglickém jazyce
Reliability of ankle–foot complex isokinetic strength assessment using the Isomed 2000 dynamometer
Popis výsledku anglicky
For quantifying muscle strength in clinical and research practice, establishing the reliability of measurements, specifically to the procedures used, is essential for credible findings. The objective was to establish the reliability of isokinetic measurement of ankle plantar and dorsal flexors (PF/DF) and invertors and evertors (INV/EV) on an IsoMed 2000 dynamometer. Twenty healthy subjects (10 males, 10 females, mean age: 23.1 ± 3.1 years) completed an isokinetic measurement session. The intraclass correlation coefficient (ICC) and standard error of measurement were assessed for peak torque and work of ankle PF/DF (concentric and eccentric) and INV/EV (concentric) for the preferred and nonpreferred limb. Standardized isokinetic measurements of reciprocal PF/DF and INV/EV muscle actions were associated with ICC ranging from 0.77 to 0.98 for the majority of observed parameters. The exception was work in the eccentric mode in the ankle DF and peak torque in the concentric mode in the ankle INV on the preferred limb, where ICC ranged from 0.64 to 0.71. The IsoMed 2000 isokinetic dynamometer can be reliably employed in future studies for reciprocal ankle PF/DF and INV/EV assessment in healthy adult subjects after implementation of a familiarization session.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ18-16107Y" target="_blank" >GJ18-16107Y: Posturální stabilita a její vztah k síle vybraných svalových skupin</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medicina-Lithuania
ISSN
1010-660X
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
LT - Litevská republika
Počet stran výsledku
11
Strana od-do
1-11
Kód UT WoS článku
000441528700012
EID výsledku v databázi Scopus
2-s2.0-85053310871