Length of the center of pressure plot: Technique for quantifying gait performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F18%3A73589781" target="_blank" >RIV/61989592:15510/18:73589781 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.23919/AE.2018.8501461" target="_blank" >http://dx.doi.org/10.23919/AE.2018.8501461</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23919/AE.2018.8501461" target="_blank" >10.23919/AE.2018.8501461</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Length of the center of pressure plot: Technique for quantifying gait performance
Popis výsledku v původním jazyce
Using information about the values of the total center of pressure (CoP) and total vertical ground reaction force (GRF) during gait, quantitative parameters based on CoP trajectory length and trajectory length of 3-D plot of vertical GRF vs. CoP can be calculated and used to compare pathological prosthetic gait and normal gait. Seven patients with right transtibial amputation using passive transtibial prostheses, and ten healthy subjects participated in the study. After calculating the parameters of each patient and healthy subject, the two-sample t-test was used to assess the significance of the differences between the results of the two groups. Also, the observed parameters were compared with each other. For this purpose, Pearson correlation coefficients between the parameters were calculated to study the relationships between the parameters. The results show that in all cases, the parameters described in patients are significantly different than in healthy subjects. New parameters provide new information on way of walking and show the differences in gait step as a whole. The described techniques and calculated and statistically evaluated values of proposed parameters can be used for gait analysis in clinical practice.
Název v anglickém jazyce
Length of the center of pressure plot: Technique for quantifying gait performance
Popis výsledku anglicky
Using information about the values of the total center of pressure (CoP) and total vertical ground reaction force (GRF) during gait, quantitative parameters based on CoP trajectory length and trajectory length of 3-D plot of vertical GRF vs. CoP can be calculated and used to compare pathological prosthetic gait and normal gait. Seven patients with right transtibial amputation using passive transtibial prostheses, and ten healthy subjects participated in the study. After calculating the parameters of each patient and healthy subject, the two-sample t-test was used to assess the significance of the differences between the results of the two groups. Also, the observed parameters were compared with each other. For this purpose, Pearson correlation coefficients between the parameters were calculated to study the relationships between the parameters. The results show that in all cases, the parameters described in patients are significantly different than in healthy subjects. New parameters provide new information on way of walking and show the differences in gait step as a whole. The described techniques and calculated and statistically evaluated values of proposed parameters can be used for gait analysis in clinical practice.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 International Conference on Applied Electronics (AE)
ISBN
978-80-261-0722-4
ISSN
1803-7232
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
85-88
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Pilsen
Datum konání akce
11. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000450228600020