For the study of total vertical ground reaction force, three Bertec force plates arranged in staggered configuration were used. Two parameters, movement direction of center of pressure during one step a peak of normalized ground reaction force, were designed to evaluate pathological prosthetic gait as a whole. Seven patients with right transtibial amputation using passive transtibial prostheses, and ten healthy subjects participated in the study. After calculating the parameters of each patient and healthy subject, the two-sample t-test was used to assess the significance of the differences between the results of the two groups. Also, the observed parameters were compared with each other. The results show that in all cases, the parameters described in patients are significantly different than in healthy subjects. New methods provide information on the gait with transtibial amputation as a whole.
Název v anglickém jazyce
Gait evaluation in patients with transtibial prosthesis using force platforms
Popis výsledku anglicky
For the study of total vertical ground reaction force, three Bertec force plates arranged in staggered configuration were used. Two parameters, movement direction of center of pressure during one step a peak of normalized ground reaction force, were designed to evaluate pathological prosthetic gait as a whole. Seven patients with right transtibial amputation using passive transtibial prostheses, and ten healthy subjects participated in the study. After calculating the parameters of each patient and healthy subject, the two-sample t-test was used to assess the significance of the differences between the results of the two groups. Also, the observed parameters were compared with each other. The results show that in all cases, the parameters described in patients are significantly different than in healthy subjects. New methods provide information on the gait with transtibial amputation as a whole.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2018 18th International Conference on Mechatronics – Mechatronika (ME) 2018
ISBN
978-80-214-5544-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
Vysoké učení technické
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
5. 12. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—