Influence of rehabilitation aid with biofeedback on the rehabilitation process during remote home-based rehabilitation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F22%3A73613320" target="_blank" >RIV/61989592:15510/22:73613320 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/22:A2302IN5 RIV/61989100:27240/22:10250225
Výsledek na webu
<a href="https://www.mdpi.com/1660-4601/19/15/9069/htm" target="_blank" >https://www.mdpi.com/1660-4601/19/15/9069/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ijerph19159069" target="_blank" >10.3390/ijerph19159069</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of rehabilitation aid with biofeedback on the rehabilitation process during remote home-based rehabilitation
Popis výsledku v původním jazyce
Ensuring the regularity and correctness of rehabilitation exercises in the home environment is a prerequisite for successful treatment. This clinical study compares balance therapy in the home environment on a conventional balance mat and an instrumented wobble board, with biofeedback supported by a rehabilitation scheme realized as web-based software that controls the course of rehabilitation remotely. The study included 55 patients with knee injuries. The control group consisted of 25 patients (12 females and 13 males, mean age 39 ± 12 years) and the study group of 30 patients (19 females and 11 males, mean age 40 ± 12 years). Treatment effects were compared using the ICS Balance Platform measurement system. Measurements showed significant differences in the change in ICS Balance platform parameters representing the dynamic stability of the patients. The dynamic stability improved more with the instrumented wobble board. The study did not show an influence of different methods of communication with patients during home-based rehabilitation
Název v anglickém jazyce
Influence of rehabilitation aid with biofeedback on the rehabilitation process during remote home-based rehabilitation
Popis výsledku anglicky
Ensuring the regularity and correctness of rehabilitation exercises in the home environment is a prerequisite for successful treatment. This clinical study compares balance therapy in the home environment on a conventional balance mat and an instrumented wobble board, with biofeedback supported by a rehabilitation scheme realized as web-based software that controls the course of rehabilitation remotely. The study included 55 patients with knee injuries. The control group consisted of 25 patients (12 females and 13 males, mean age 39 ± 12 years) and the study group of 30 patients (19 females and 11 males, mean age 40 ± 12 years). Treatment effects were compared using the ICS Balance Platform measurement system. Measurements showed significant differences in the change in ICS Balance platform parameters representing the dynamic stability of the patients. The dynamic stability improved more with the instrumented wobble board. The study did not show an influence of different methods of communication with patients during home-based rehabilitation
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30304 - Public and environmental health
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_049%2F0008441" target="_blank" >EF17_049/0008441: Inovativní léčebné metody pohybového aparátu v úrazové chirurgii</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Research and Public Health
ISSN
1660-4601
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000838942900001
EID výsledku v databázi Scopus
2-s2.0-85135376141