Experimental Measurement and Energy Evaluation of the Geothermal Water Energy Utilization in a Thermal Swimming Pool
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43110%2F25%3A43927171" target="_blank" >RIV/62156489:43110/25:43927171 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3311/PPme.38200" target="_blank" >https://doi.org/10.3311/PPme.38200</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3311/PPme.38200" target="_blank" >10.3311/PPme.38200</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental Measurement and Energy Evaluation of the Geothermal Water Energy Utilization in a Thermal Swimming Pool
Popis výsledku v původním jazyce
This work focuses on the experimental measurement of the temperature and flow of cold, geothermal, pool and waste pool water of a thermal swimming pool in southern Slovakia. The measured quantities are necessary for the energy evaluation of geothermal water energy utilization. It is clear from experience that the geothermal energy utilization rate often does not even reach 40%. The remaining energy is considered waste, and in the form of waste pool water with too high temperature, it is most often discharged into surface streams. The results of the study showed that by applying appropriate measures to recover heat from waste pool water, it is possible to increase the energy utilization rate of thermal water from 40% to 85%, which is the ideal energy utilization rate according to energy point of view. At the end of the article, methods will be presented, thanks to which it would be possible to reduce the temperature of waste pool water to the value required by law and at the same time increase the rate of thermal water energy use.
Název v anglickém jazyce
Experimental Measurement and Energy Evaluation of the Geothermal Water Energy Utilization in a Thermal Swimming Pool
Popis výsledku anglicky
This work focuses on the experimental measurement of the temperature and flow of cold, geothermal, pool and waste pool water of a thermal swimming pool in southern Slovakia. The measured quantities are necessary for the energy evaluation of geothermal water energy utilization. It is clear from experience that the geothermal energy utilization rate often does not even reach 40%. The remaining energy is considered waste, and in the form of waste pool water with too high temperature, it is most often discharged into surface streams. The results of the study showed that by applying appropriate measures to recover heat from waste pool water, it is possible to increase the energy utilization rate of thermal water from 40% to 85%, which is the ideal energy utilization rate according to energy point of view. At the end of the article, methods will be presented, thanks to which it would be possible to reduce the temperature of waste pool water to the value required by law and at the same time increase the rate of thermal water energy use.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Periodica Polytechnica Mechanical Engineering
ISSN
0324-6051
e-ISSN
1587-379X
Svazek periodika
69
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
9
Strana od-do
112-120
Kód UT WoS článku
001462887000001
EID výsledku v databázi Scopus
2-s2.0-105007288866