Stanovení flavonoidů pomocí SWV
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F05%3A00007474" target="_blank" >RIV/62156489:43210/05:00007474 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of flavonoids using of square wave voltammetry
Popis výsledku v původním jazyce
The possible relation of flavonoid compounds and tumour diseases has been recently published. On the other hand it is hard to say that the impact of flavonoids on tumour diseases treatment is positive or negative without epidemiological studies. That iswhy it is necessary to suggest a simple, low cost and sensitive technique for determination of these compounds in biological material. Electrochemical measurements were performed with AUTOLAB Analyser (EcoChemie, Netherlands) connected to VA-Stand 663 (Metrohm, Switzerland), using a standard cell with three electrodes. The working electrode was a carbon paste electrode. The reference electrode was an Ag/AgCl/3M KCl electrode and the auxiliary electrode was a graphite electrode. The supporting electrolyte was prepared by mixing buffer components. The measurements were performed using the following parameters: initial potential = 0.1 V, end potential = 1.2 V, pulse amplitude = 49.85 mV, step potential = 1.95 mV, and frequency = 180 Hz. Ph
Název v anglickém jazyce
Determination of flavonoids using of square wave voltammetry
Popis výsledku anglicky
The possible relation of flavonoid compounds and tumour diseases has been recently published. On the other hand it is hard to say that the impact of flavonoids on tumour diseases treatment is positive or negative without epidemiological studies. That iswhy it is necessary to suggest a simple, low cost and sensitive technique for determination of these compounds in biological material. Electrochemical measurements were performed with AUTOLAB Analyser (EcoChemie, Netherlands) connected to VA-Stand 663 (Metrohm, Switzerland), using a standard cell with three electrodes. The working electrode was a carbon paste electrode. The reference electrode was an Ag/AgCl/3M KCl electrode and the auxiliary electrode was a graphite electrode. The supporting electrolyte was prepared by mixing buffer components. The measurements were performed using the following parameters: initial potential = 0.1 V, end potential = 1.2 V, pulse amplitude = 49.85 mV, step potential = 1.95 mV, and frequency = 180 Hz. Ph
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP525%2F04%2FP132" target="_blank" >GP525/04/P132: Studium obranných mechanismů rostlin při stresu způsobeném těžkými kovy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Vitamins 2005 - Targeted Nutritional Therapy
ISBN
80-7194-748-2
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
175-176
Název nakladatele
Univerzita Pardubice
Místo vydání
Pardubice, Czech Republic
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—