Stanovení stříbrných iontů v pitné vodě užitím průtokové injekční analýzy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F08%3A00124782" target="_blank" >RIV/62156489:43210/08:00124782 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of silver ions in drinking waters by using flow injection analysis (FIA)
Popis výsledku v původním jazyce
Determination of heavy metals in drinking waters and biological samples belongs among the actual questions in food hygiene, food quality and food chemistry. Silver is toxic for all organisms, especially for those who live in water. Due to its presence inwastewaters is necessary to study their fate in the environment. The electrochemical methods are alternative analytic techniques that make the silver ions determination possible in nM concentrations, mainly using carbon electrodes. In the presented workthe releasing of silver ions into Milli-Q water, distilled water, tap water from city Brno, common mineral waters, tasted mineral waters and lemonades was studied in 13 week experiment. The silver ions released from silver plate placed into the sample were detected after four weeks, the average determined concentration of silver ions at the beginning of the experiment was 7.34+-2.79 nM, at the end of the experiment the determined concentration
Název v anglickém jazyce
Determination of silver ions in drinking waters by using flow injection analysis (FIA)
Popis výsledku anglicky
Determination of heavy metals in drinking waters and biological samples belongs among the actual questions in food hygiene, food quality and food chemistry. Silver is toxic for all organisms, especially for those who live in water. Due to its presence inwastewaters is necessary to study their fate in the environment. The electrochemical methods are alternative analytic techniques that make the silver ions determination possible in nM concentrations, mainly using carbon electrodes. In the presented workthe releasing of silver ions into Milli-Q water, distilled water, tap water from city Brno, common mineral waters, tasted mineral waters and lemonades was studied in 13 week experiment. The silver ions released from silver plate placed into the sample were detected after four weeks, the average determined concentration of silver ions at the beginning of the experiment was 7.34+-2.79 nM, at the end of the experiment the determined concentration
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA526%2F07%2F0674" target="_blank" >GA526/07/0674: Ultrasenzitivní analýza stříbra ve vodách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Bezpečnosť a kvalita surovín a potravín
ISBN
978-80-8069-996-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
127-132
Název nakladatele
FBP SPU Nitra
Místo vydání
Nitra, Slovensko
Místo konání akce
SPU Nitra
Datum konání akce
1. 1. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—