Použití elektroanalytických technik pro detekci stříbrných iontů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F08%3A00133456" target="_blank" >RIV/62156489:43210/08:00133456 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Employing of electroanalytical techniques for detection of silver (I) ions
Popis výsledku v původním jazyce
The aim of this work was to detect silver ions by using various electrochemical instruments. Carbon electrodes were tested as working electrodes. The optimized procedures were utilized for determination of silver(I) at BY-2 tobacco cells and guppy fishestreated with the silver(I) ions. Moreover we optimized the basic experimental parameters of the high performance liquid chromatography with electrochemical detection (HPLC-ED) to determine silver(I) ions. The most suitable parameters for the determination of silver ions were as follows--mobile phase 0.2M acetate buffer (pH 4.0) and its flow rate: 0.5 ml/min, guard cell potential: 0 mV, working electrode potential: 200 mV, current R: 1 uA, time filter: 2 s. The detection limit obtained was 20 nmol/dm3.The content of silver(I) ions determined in the treated BY-2 cells enhanced with increasing dose of the silver(I) ions and time of the treatment.
Název v anglickém jazyce
Employing of electroanalytical techniques for detection of silver (I) ions
Popis výsledku anglicky
The aim of this work was to detect silver ions by using various electrochemical instruments. Carbon electrodes were tested as working electrodes. The optimized procedures were utilized for determination of silver(I) at BY-2 tobacco cells and guppy fishestreated with the silver(I) ions. Moreover we optimized the basic experimental parameters of the high performance liquid chromatography with electrochemical detection (HPLC-ED) to determine silver(I) ions. The most suitable parameters for the determination of silver ions were as follows--mobile phase 0.2M acetate buffer (pH 4.0) and its flow rate: 0.5 ml/min, guard cell potential: 0 mV, working electrode potential: 200 mV, current R: 1 uA, time filter: 2 s. The detection limit obtained was 20 nmol/dm3.The content of silver(I) ions determined in the treated BY-2 cells enhanced with increasing dose of the silver(I) ions and time of the treatment.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA526%2F07%2F0674" target="_blank" >GA526/07/0674: Ultrasenzitivní analýza stříbra ve vodách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Toxicology Letters
ISSN
0378-4274
e-ISSN
—
Svazek periodika
180
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
2
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—