Polyelectrolyte multilayers as stationary phases for open tubular ion chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F09%3A00142253" target="_blank" >RIV/62156489:43210/09:00142253 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Polyelectrolyte multilayers as stationary phases for open tubular ion chromatography
Popis výsledku v původním jazyce
Polyelectrolyte multilayers deposited on the wall of fused silica capillaries were for the first time used as stationary phases in open tubular ion chromatography. The multilayers are formed by flushing the capillaries with solutions of polyanions and polycations such as polydiallydimethylammonium chloride and dextran sulphate. Columns with several bi-layers are constructed and used in low pressure open tubular ion chromatohraphy of common inorganic anions and/or cations. We demonstrate separation of three common anions and five cations in a non-suppressed IC mode with sodium benzoate and tartaric acid eluents using a contactless conductometric detection. We further show that it is possible to prepare a bi-functional column that contains both anionic and cationic functional groups and can be used for simultaneous separation of anions and cations.
Název v anglickém jazyce
Polyelectrolyte multilayers as stationary phases for open tubular ion chromatography
Popis výsledku anglicky
Polyelectrolyte multilayers deposited on the wall of fused silica capillaries were for the first time used as stationary phases in open tubular ion chromatography. The multilayers are formed by flushing the capillaries with solutions of polyanions and polycations such as polydiallydimethylammonium chloride and dextran sulphate. Columns with several bi-layers are constructed and used in low pressure open tubular ion chromatohraphy of common inorganic anions and/or cations. We demonstrate separation of three common anions and five cations in a non-suppressed IC mode with sodium benzoate and tartaric acid eluents using a contactless conductometric detection. We further show that it is possible to prepare a bi-functional column that contains both anionic and cationic functional groups and can be used for simultaneous separation of anions and cations.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F07%2F0983" target="_blank" >GA203/07/0983: Vývoj nových stacionárních fází na bázi vícevrstvých polymerů pro iontovou chromatografii v otevřených kapilárních kolonách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1216
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—