Assessment of antioxidant capacity by using of cyclic voltammetry - Clinical application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F09%3A00152828" target="_blank" >RIV/62156489:43210/09:00152828 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of antioxidant capacity by using of cyclic voltammetry - Clinical application
Popis výsledku v původním jazyce
It is a common knowledge that oxidative stress relates with imbalance between concentration of prooxidants and the antioxidant. Moreover, it appears that these changes are very important in the pathophysiology of critically ill patients. The main aim ofthis contribution is to study antioxidant activity by using of cyclic voltammetry (CV) at carbon working electrodes. For measuring antioxidant capacity, we utilized carbon paste electrodes, which are easy to prepare. As a part of carbon paste, microparticles of sizes 2-5 mm (expanded carbon and carbon nanoparticles) were used. Acetate and phosphate buffers were tested as the supporting electrolytes. In animal organisms ascorbic and uric acids belong to the important antioxidants. Therefore, these two dominant antioxidants were investigated by using of above-mentioned CV at carbon paste electrodes. For the assessment of antioxidant capacity the sum of the areas of all signals measured in the samples were used. The highest signals were de
Název v anglickém jazyce
Assessment of antioxidant capacity by using of cyclic voltammetry - Clinical application
Popis výsledku anglicky
It is a common knowledge that oxidative stress relates with imbalance between concentration of prooxidants and the antioxidant. Moreover, it appears that these changes are very important in the pathophysiology of critically ill patients. The main aim ofthis contribution is to study antioxidant activity by using of cyclic voltammetry (CV) at carbon working electrodes. For measuring antioxidant capacity, we utilized carbon paste electrodes, which are easy to prepare. As a part of carbon paste, microparticles of sizes 2-5 mm (expanded carbon and carbon nanoparticles) were used. Acetate and phosphate buffers were tested as the supporting electrolytes. In animal organisms ascorbic and uric acids belong to the important antioxidants. Therefore, these two dominant antioxidants were investigated by using of above-mentioned CV at carbon paste electrodes. For the assessment of antioxidant capacity the sum of the areas of all signals measured in the samples were used. The highest signals were de
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KAN208130801" target="_blank" >KAN208130801: Nové konstrukce a využití nanobiosenzorů a nanosenzorů v medicíně (NANOSEMED)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Antioxidanty 2009: zborník z I. ročníka vedeckej konferencie s medzinárodnou účasťou
ISBN
978-80-552-0209-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
103-106
Název nakladatele
SPU
Místo vydání
Nitra
Místo konání akce
Nitra
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—