Off-line coupling of automated pipetting system with square wave voltammetry as a tool for study of drug-DNA interaction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F10%3A00166509" target="_blank" >RIV/62156489:43210/10:00166509 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Off-line coupling of automated pipetting system with square wave voltammetry as a tool for study of drug-DNA interaction
Popis výsledku v původním jazyce
Manual handling with DNA and drugs can be a source of errors, which can be eliminated also by automation of whole process of sample preparation. The aim of this work was to study interaction between DNA and ellipticine by using of off-line coupled automated pipetting system with adsorptive transfer stripping technique (AdTS) square wave voltammetry (SWV). Interaction between dsDNA and ellipticine was evident from the decrease of CA signal. Six ng of ellipticine per ml resulted in a statistically significant decrease in CA signal (the decrease was higher than the standard deviation of determinations, Student t-test). The decrease in CA signal corresponded to increasing ellipticine concentrations.
Název v anglickém jazyce
Off-line coupling of automated pipetting system with square wave voltammetry as a tool for study of drug-DNA interaction
Popis výsledku anglicky
Manual handling with DNA and drugs can be a source of errors, which can be eliminated also by automation of whole process of sample preparation. The aim of this work was to study interaction between DNA and ellipticine by using of off-line coupled automated pipetting system with adsorptive transfer stripping technique (AdTS) square wave voltammetry (SWV). Interaction between dsDNA and ellipticine was evident from the decrease of CA signal. Six ng of ellipticine per ml resulted in a statistically significant decrease in CA signal (the decrease was higher than the standard deviation of determinations, Student t-test). The decrease in CA signal corresponded to increasing ellipticine concentrations.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F08%2F1546" target="_blank" >GA102/08/1546: Miniaturizované inteligentní systémy a nanostrukturované elektrody pro chemické, biologické a farmaceutické aplikace (NANIMEL)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chimica Oggi - Chemistry Today
ISSN
0392-839X
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—