Comparison of soil frost depth and its duration determined by soil frost tube and soil temperature interpolation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F12%3A00193338" target="_blank" >RIV/62156489:43210/12:00193338 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of soil frost depth and its duration determined by soil frost tube and soil temperature interpolation
Popis výsledku v původním jazyce
Soil frost and the depth of freezing are important for the plant development and for the building industry as well. The depth of soil frost is estimated directly by soil frost tube and indirectly from diagrams of soil temperature according to the isotherm of 0 °C (zero-isotherm). The soil temperature measurement is often used for evaluation of freezing depth, because the frost tubes measurement is rarely performed. Measurement by frost tube is done once a day at 7 a.m. and soil temperature in 5, 10, 20,50 and 100 cm is measured in three observation terms at 7 a.m., 2 p.m. and 9 p.m. Data from agroclimatological station Pohorelice (1971-2000) were used for the evaluation. Three specific real cold periods (1978-1979, 1984-1985 and 1990-1991) and mean frost depth and absolute maximal frost depth for the whole period were evaluated. Course of frost, terms of beginning and the end of frost period and the term of maximum freezing assessed by both methods are almost identical in all real eva
Název v anglickém jazyce
Comparison of soil frost depth and its duration determined by soil frost tube and soil temperature interpolation
Popis výsledku anglicky
Soil frost and the depth of freezing are important for the plant development and for the building industry as well. The depth of soil frost is estimated directly by soil frost tube and indirectly from diagrams of soil temperature according to the isotherm of 0 °C (zero-isotherm). The soil temperature measurement is often used for evaluation of freezing depth, because the frost tubes measurement is rarely performed. Measurement by frost tube is done once a day at 7 a.m. and soil temperature in 5, 10, 20,50 and 100 cm is measured in three observation terms at 7 a.m., 2 p.m. and 9 p.m. Data from agroclimatological station Pohorelice (1971-2000) were used for the evaluation. Three specific real cold periods (1978-1979, 1984-1985 and 1990-1991) and mean frost depth and absolute maximal frost depth for the whole period were evaluated. Course of frost, terms of beginning and the end of frost period and the term of maximum freezing assessed by both methods are almost identical in all real eva
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DF - Pedologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/QH82099" target="_blank" >QH82099: Kriteria rozvoje větrné eroze na těžkých půdách a možnosti jejího omezení biotechnickými opatřeními</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Contributions to Geophysics and Geodesy
ISSN
1335-2806
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
14
Strana od-do
255-268
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—