Analysis of cadmium-phytochelatins 2 complexes using flow injection analysis coupled with electrochemical detection mass spectrometry
Popis výsledku v původním jazyce
In this study, in vitro synthesized Cd-phytochelatin (PC2) complexes were characterized using flow injection analysis/high performance liquid chromatography with CoulArray or Coulochem electrochemical detector of PC2 and Cd-PC2 complexes. Method of the formation of complex by the matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF-MS) was confirmed. Higher pH had lowered effect for Cd(II) detection but PC2 detection suffers much in task of sensitivity and for furtheranalysis we thus used the Britton-Robinson buffer at pH 2 as electrolyte. Higher temperature than 40 °C positively influenced the interaction between Cd and thiol groups of PC2 by Coulochem III. The time did not affect the forming of complex. The concentration had bigger effect on the formation of complex than time of incubation. The biggest change was, with regards to concentration, observed under applied concentration 400 ug/ml and where the slope was the most decreasing which means th
Název v anglickém jazyce
Analysis of cadmium-phytochelatins 2 complexes using flow injection analysis coupled with electrochemical detection mass spectrometry
Popis výsledku anglicky
In this study, in vitro synthesized Cd-phytochelatin (PC2) complexes were characterized using flow injection analysis/high performance liquid chromatography with CoulArray or Coulochem electrochemical detector of PC2 and Cd-PC2 complexes. Method of the formation of complex by the matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF-MS) was confirmed. Higher pH had lowered effect for Cd(II) detection but PC2 detection suffers much in task of sensitivity and for furtheranalysis we thus used the Britton-Robinson buffer at pH 2 as electrolyte. Higher temperature than 40 °C positively influenced the interaction between Cd and thiol groups of PC2 by Coulochem III. The time did not affect the forming of complex. The concentration had bigger effect on the formation of complex than time of incubation. The biggest change was, with regards to concentration, observed under applied concentration 400 ug/ml and where the slope was the most decreasing which means th
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
13
Strana od-do
4409-4421