Measurement of basic operating parameters of vacuum pump and electromotor on laboratory milking equipment controlled by frequency converter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F14%3A00229402" target="_blank" >RIV/62156489:43210/14:00229402 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of basic operating parameters of vacuum pump and electromotor on laboratory milking equipment controlled by frequency converter
Popis výsledku v původním jazyce
The desired vacuum pressure level in milking process is nowadays achieved by using rotary vane vacuum pump that is driven by squirrel-cage induction motor. The vacuum pressure regulation was until recent achieved by correctly set automatic regulation valve in the way that it sucked in the atmospheric air from the outside of the system. There was therefore big power consumption because of this type of regulation -- electromotor had to run at full power all the time. Development of frequency converters brought the possibility of power saving. Frequency converters control the electromotor so that the real performance of the vacuum pump is proportional to the air amount sucked in the system. This paper deals with correct settings of input parameters of frequency converter and describes basic values of electromotor and vacuum pump. This paper also contains flow characteristics of used vacuum pump for different speeds.
Název v anglickém jazyce
Measurement of basic operating parameters of vacuum pump and electromotor on laboratory milking equipment controlled by frequency converter
Popis výsledku anglicky
The desired vacuum pressure level in milking process is nowadays achieved by using rotary vane vacuum pump that is driven by squirrel-cage induction motor. The vacuum pressure regulation was until recent achieved by correctly set automatic regulation valve in the way that it sucked in the atmospheric air from the outside of the system. There was therefore big power consumption because of this type of regulation -- electromotor had to run at full power all the time. Development of frequency converters brought the possibility of power saving. Frequency converters control the electromotor so that the real performance of the vacuum pump is proportional to the air amount sucked in the system. This paper deals with correct settings of input parameters of frequency converter and describes basic values of electromotor and vacuum pump. This paper also contains flow characteristics of used vacuum pump for different speeds.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník příspěvků z mezinárodní vědecké konference MMK 2014: Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky.
ISBN
978-80-87952-07-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4023
Strana od-do
325-433
Název nakladatele
MAGNANIMITAS
Místo vydání
Hradec Králové
Místo konání akce
Hradec Králové
Datum konání akce
1. 1. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce