Capability of the Measuring Equipment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F17%3A43912918" target="_blank" >RIV/62156489:43210/17:43912918 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capability of the Measuring Equipment
Popis výsledku v původním jazyce
The aim of the article is to practically illustrate the methodologies and verify the capability of measuring equipment in the production organization. The methodologies have been shown in measuring station in the production process of the lid torque converter. The first method that we used was the study bias measurement system by which we acquired capability indexes Cgm, Cgmk. The resultant values of the capability indexes Cgm = 2,154 and Cgmk = 1,378 meet the eligibility requirements according to the measuring device Cgm GREATER-THAN OR EQUAL TO1,34, Cgmk GREATER-THAN OR EQUAL TO1,33. The second used methodology was the method of repeatability and reproducibility R&R, where we calculated the result % R&R = 27,7 %. It shows us that the value of % R&R is in the range of 10 - 30 % of the variance (or tolerance). The measuring system is conditionally suitable depending on the importance of application, cost of repair and gauge. Some corrective measures are needed depending on the use of the measuring equipment. As a measuring device, we used measuring station from the Marposs manufacturer.
Název v anglickém jazyce
Capability of the Measuring Equipment
Popis výsledku anglicky
The aim of the article is to practically illustrate the methodologies and verify the capability of measuring equipment in the production organization. The methodologies have been shown in measuring station in the production process of the lid torque converter. The first method that we used was the study bias measurement system by which we acquired capability indexes Cgm, Cgmk. The resultant values of the capability indexes Cgm = 2,154 and Cgmk = 1,378 meet the eligibility requirements according to the measuring device Cgm GREATER-THAN OR EQUAL TO1,34, Cgmk GREATER-THAN OR EQUAL TO1,33. The second used methodology was the method of repeatability and reproducibility R&R, where we calculated the result % R&R = 27,7 %. It shows us that the value of % R&R is in the range of 10 - 30 % of the variance (or tolerance). The measuring system is conditionally suitable depending on the importance of application, cost of repair and gauge. Some corrective measures are needed depending on the use of the measuring equipment. As a measuring device, we used measuring station from the Marposs manufacturer.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agricultural, Forest and Transport Machinery and Technologies
ISSN
2367-5888
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
BG - Bulharská republika
Počet stran výsledku
9
Strana od-do
13-21
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—