Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F19%3A43915098" target="_blank" >RIV/62156489:43210/19:43915098 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216275:25310/19:39914669
Výsledek na webu
<a href="https://doi.org/10.1016/j.microc.2018.12.053" target="_blank" >https://doi.org/10.1016/j.microc.2018.12.053</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2018.12.053" target="_blank" >10.1016/j.microc.2018.12.053</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode
Popis výsledku v původním jazyce
Bismuth-oxychloride-multiwalled carbon nanotube composite material was applied as surface modifier of glassy carbon electrode (BiOCl-MWCNT/GCE) for rapid and reliable trace level determination of Zn(II) in selected foodstuffs. The method development encompasses the optimization of electrode preparation including the transmission electron microscopic study of the modifier suspension, selection of the supporting electrolyte pH, the adjustment of the operation parameters of the SW-ASV measurements and the investigation of matrix effects. By the BiOCl-MWCNT/GCE recorded calibration curve showed an excellent linearity towards Zn reoxidation peak intensity in the concentration range from 2.50 to 80.0 μg LMINUS SIGN 1 with the calculated LOD of 0.75 μg LMINUS SIGN 1 which was associated with 120 s accumulation time and accumulation potential MINUS SIGN 1.40 V vs SCE in acetate buffer pH 4.5. A satisfactory repeatability expressed as relative standard deviation of 4.8% was obtained in the case of 10.0 μg LMINUS SIGN 1 Zn(II) in model solution. The Zn(II) reoxidation signal from BiOCl-MWCNT/GCE received by the optimized SW-ASV method was compared with those recorded with bare, classical bismuth-film, multiwalled carbon nanotubes and by in situ made advanced bismuth-film-MWCNTs working electrodes. The applicability of the proposed BiOCl-MWCNT/GCE based method was corroborated via measuring the target analyte in two nutrition related real samples: in a dietary supplement and in a brewer's yeast sample. Comparative flame atomic absorption spectrometric measurements verified the obtained results in the case of yeast sample.
Název v anglickém jazyce
Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode
Popis výsledku anglicky
Bismuth-oxychloride-multiwalled carbon nanotube composite material was applied as surface modifier of glassy carbon electrode (BiOCl-MWCNT/GCE) for rapid and reliable trace level determination of Zn(II) in selected foodstuffs. The method development encompasses the optimization of electrode preparation including the transmission electron microscopic study of the modifier suspension, selection of the supporting electrolyte pH, the adjustment of the operation parameters of the SW-ASV measurements and the investigation of matrix effects. By the BiOCl-MWCNT/GCE recorded calibration curve showed an excellent linearity towards Zn reoxidation peak intensity in the concentration range from 2.50 to 80.0 μg LMINUS SIGN 1 with the calculated LOD of 0.75 μg LMINUS SIGN 1 which was associated with 120 s accumulation time and accumulation potential MINUS SIGN 1.40 V vs SCE in acetate buffer pH 4.5. A satisfactory repeatability expressed as relative standard deviation of 4.8% was obtained in the case of 10.0 μg LMINUS SIGN 1 Zn(II) in model solution. The Zn(II) reoxidation signal from BiOCl-MWCNT/GCE received by the optimized SW-ASV method was compared with those recorded with bare, classical bismuth-film, multiwalled carbon nanotubes and by in situ made advanced bismuth-film-MWCNTs working electrodes. The applicability of the proposed BiOCl-MWCNT/GCE based method was corroborated via measuring the target analyte in two nutrition related real samples: in a dietary supplement and in a brewer's yeast sample. Comparative flame atomic absorption spectrometric measurements verified the obtained results in the case of yeast sample.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microchemical Journal
ISSN
0026-265X
e-ISSN
—
Svazek periodika
146
Číslo periodika v rámci svazku
May
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
178-186
Kód UT WoS článku
000463132100023
EID výsledku v databázi Scopus
2-s2.0-85059519711