Defining of Thermal Bridges of Wood Building and Their Elimination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43410%2F16%3A43909853" target="_blank" >RIV/62156489:43410/16:43909853 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.centrumdp.sk/wr/201604/10.pdf" target="_blank" >http://www.centrumdp.sk/wr/201604/10.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Defining of Thermal Bridges of Wood Building and Their Elimination
Popis výsledku v původním jazyce
The thesis focuses on the matter of thermal bridges in case of wooden panel structures, both in case of low-energy and passive structure-standard. Thermography was used for localization of critical areas of structures details of corner joints of external walls and ceiling connections. The values subject to comparison are the linear coefficient of heat penetration from the exterior and the lowest interior surface temperature. This results in the overall comparison of both the structures as well as elimination of the excessive heat flow, whereas the difference in detail of corner joints of external walls is 0.03 W.(m.K)(-1) for both, and the difference in detail of the ceiling connections equals 0.07 and 0.08 W.(m.K)(-1) respectively. The difference in the lowest interior surface temperature in detail of corner joints of external walls for both structures equals 1.34 and 2.99 degrees C respectively, and in the detail of the ceiling connections the difference is 2.45 degrees C.
Název v anglickém jazyce
Defining of Thermal Bridges of Wood Building and Their Elimination
Popis výsledku anglicky
The thesis focuses on the matter of thermal bridges in case of wooden panel structures, both in case of low-energy and passive structure-standard. Thermography was used for localization of critical areas of structures details of corner joints of external walls and ceiling connections. The values subject to comparison are the linear coefficient of heat penetration from the exterior and the lowest interior surface temperature. This results in the overall comparison of both the structures as well as elimination of the excessive heat flow, whereas the difference in detail of corner joints of external walls is 0.03 W.(m.K)(-1) for both, and the difference in detail of the ceiling connections equals 0.07 and 0.08 W.(m.K)(-1) respectively. The difference in the lowest interior surface temperature in detail of corner joints of external walls for both structures equals 1.34 and 2.99 degrees C respectively, and in the detail of the ceiling connections the difference is 2.45 degrees C.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Wood Research
ISSN
1336-4561
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
8
Strana od-do
607-614
Kód UT WoS článku
000383729800010
EID výsledku v databázi Scopus
2-s2.0-84991624950