Influence of exhaust system setup on working zone pollution by dust during sawing of particleboards
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43410%2F20%3A43917919" target="_blank" >RIV/62156489:43410/20:43917919 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/ijerph17103626" target="_blank" >https://doi.org/10.3390/ijerph17103626</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ijerph17103626" target="_blank" >10.3390/ijerph17103626</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of exhaust system setup on working zone pollution by dust during sawing of particleboards
Popis výsledku v původním jazyce
Air pollution by wood dust in furniture production sites is an important hygiene issue. The dust is created by all types of wood and wood-based material machining, and its concentration in the working zone surrounding the machining stand depends on the effectiveness of the dust exhaust system. In present research, three setups of the dust extraction system for a conventional table sawing machine are considered while machining particleboards. The results showed a high impact of the exhaust system connection setup on the dust concentration in the air surrounding the sawing machine work stand. The use of both main and auxiliary sawdust extraction connectors together ensured the highest clearness of the air, with only 0.5 mg/m3 of dust concentration. Closing the upper hood leads to a concentration five times higher, while disconnecting it results in a ten times higher dust content. The finest dust particles (<1 µm), however, are the most numerous in the case of closing the hood.
Název v anglickém jazyce
Influence of exhaust system setup on working zone pollution by dust during sawing of particleboards
Popis výsledku anglicky
Air pollution by wood dust in furniture production sites is an important hygiene issue. The dust is created by all types of wood and wood-based material machining, and its concentration in the working zone surrounding the machining stand depends on the effectiveness of the dust exhaust system. In present research, three setups of the dust extraction system for a conventional table sawing machine are considered while machining particleboards. The results showed a high impact of the exhaust system connection setup on the dust concentration in the air surrounding the sawing machine work stand. The use of both main and auxiliary sawdust extraction connectors together ensured the highest clearness of the air, with only 0.5 mg/m3 of dust concentration. Closing the upper hood leads to a concentration five times higher, while disconnecting it results in a ten times higher dust content. The finest dust particles (<1 µm), however, are the most numerous in the case of closing the hood.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30305 - Occupational health
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Research and Public Health
ISSN
1661-7827
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
9
Strana od-do
3626
Kód UT WoS článku
000539300900283
EID výsledku v databázi Scopus
2-s2.0-85085270633