Rate of chainsaw vibrations in laboratory conditions and level of chainsaw noise at different distances
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43410%2F23%3A43924202" target="_blank" >RIV/62156489:43410/23:43924202 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.46490/BF638" target="_blank" >https://doi.org/10.46490/BF638</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.46490/BF638" target="_blank" >10.46490/BF638</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rate of chainsaw vibrations in laboratory conditions and level of chainsaw noise at different distances
Popis výsledku v původním jazyce
The study is focused on the rate of vibrations and level of noise in the chainsaw model Stihl MS 362 which belongs in the group of the best-selling professional chainsaws in the world with a highly efficient anti-vibration system. Testing cuts to determine the rate of vibrations were made on the stems of two tree species: sessile oak (Quercus petraea (Matt.) Liebl.) and Norway spruce (Picea abies (L.) H. Karst.). The purpose of noise level measurement was to compare the influence of chainsaw noise on its operator and on the person occurring behind the zone of protection (5 and 10 metres) from the source of noise. Then a distance from the chainsaw was measured where the level of noise reached 80 dB. The measurements were performed according to ČSN EN ISO 22868:2021. At measuring the chainsaw vibrations, the rate of vibrations acting on both operator's hands (front and rear grip) was examined. Vibrations were measured according to ČSN EN ISO 22867 (2012). It was found out that the rate of vibrations on the rear handle was in both cases of measurements higher than the rate of vibrations on the front handle. At the same time, a higher rate of vibrations was recorded in sessile oak. As to the level of noise, results of measurements indicated that at working with the chainsaw, hearing protectors have to be used at all three measured distances (close proximity, 5 m from the operator, 10 m from the operator) in order to reduce high noise level as the average noise level was higher than permissible in all measurements. The highest possible tolerable level of acoustic noise (80 dB) at which permanent damage of hearing does not happen was measured at a distance of 21 m from the working place of chainsaw operator.
Název v anglickém jazyce
Rate of chainsaw vibrations in laboratory conditions and level of chainsaw noise at different distances
Popis výsledku anglicky
The study is focused on the rate of vibrations and level of noise in the chainsaw model Stihl MS 362 which belongs in the group of the best-selling professional chainsaws in the world with a highly efficient anti-vibration system. Testing cuts to determine the rate of vibrations were made on the stems of two tree species: sessile oak (Quercus petraea (Matt.) Liebl.) and Norway spruce (Picea abies (L.) H. Karst.). The purpose of noise level measurement was to compare the influence of chainsaw noise on its operator and on the person occurring behind the zone of protection (5 and 10 metres) from the source of noise. Then a distance from the chainsaw was measured where the level of noise reached 80 dB. The measurements were performed according to ČSN EN ISO 22868:2021. At measuring the chainsaw vibrations, the rate of vibrations acting on both operator's hands (front and rear grip) was examined. Vibrations were measured according to ČSN EN ISO 22867 (2012). It was found out that the rate of vibrations on the rear handle was in both cases of measurements higher than the rate of vibrations on the front handle. At the same time, a higher rate of vibrations was recorded in sessile oak. As to the level of noise, results of measurements indicated that at working with the chainsaw, hearing protectors have to be used at all three measured distances (close proximity, 5 m from the operator, 10 m from the operator) in order to reduce high noise level as the average noise level was higher than permissible in all measurements. The highest possible tolerable level of acoustic noise (80 dB) at which permanent damage of hearing does not happen was measured at a distance of 21 m from the working place of chainsaw operator.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
40102 - Forestry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Baltic Forestry
ISSN
1392-1355
e-ISSN
2029-9230
Svazek periodika
29
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
LT - Litevská republika
Počet stran výsledku
9
Strana od-do
"id638"
Kód UT WoS článku
001146848400006
EID výsledku v databázi Scopus
2-s2.0-85176467055