Design of a vacuum pump control by a frequency converter and checks of its parameters on a functional model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A_____%2F03%3A22700015" target="_blank" >RIV/62156489:_____/03:22700015 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of a vacuum pump control by a frequency converter and checks of its parameters on a functional model
Popis výsledku v původním jazyce
The paper deals with a possible energy saving on milking machines by changing the method of vacuum regulation and by controlling the run of the vacuum pump electric motor by a frequency converter. The work was focused on defining working parameters of anewly designed device and on measuring energy consumption. The device works on the principle of a pressure-reducing valve, the vacuum pump vacuum being higher than the milking machine working vacuum. First of all it was necessary to find the minimum difference between both vacuums. Based on the measurements implemented the minimum value of the differences, i.e 4 kPa, was suggested at which energy consumption on a model device was measured. The values obtained by using the suggested regulating device andfrequency converter were compared with the values obtained by using a standard control valve and without frequency converter.
Název v anglickém jazyce
Design of a vacuum pump control by a frequency converter and checks of its parameters on a functional model
Popis výsledku anglicky
The paper deals with a possible energy saving on milking machines by changing the method of vacuum regulation and by controlling the run of the vacuum pump electric motor by a frequency converter. The work was focused on defining working parameters of anewly designed device and on measuring energy consumption. The device works on the principle of a pressure-reducing valve, the vacuum pump vacuum being higher than the milking machine working vacuum. First of all it was necessary to find the minimum difference between both vacuums. Based on the measurements implemented the minimum value of the differences, i.e 4 kPa, was suggested at which energy consumption on a model device was measured. The values obtained by using the suggested regulating device andfrequency converter were compared with the values obtained by using a standard control valve and without frequency converter.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Inžynieria Rolniczna
ISSN
1429-7264
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
8
Strana od-do
369-376