Limitations of ultrasound guided follicular aspiration for analysis of ovarian follicular fluid in dairy cattle
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16170%2F11%3A43870732" target="_blank" >RIV/62157124:16170/11:43870732 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2754/avb201180020179" target="_blank" >http://dx.doi.org/10.2754/avb201180020179</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2754/avb201180020179" target="_blank" >10.2754/avb201180020179</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Limitations of ultrasound guided follicular aspiration for analysis of ovarian follicular fluid in dairy cattle
Popis výsledku v původním jazyce
The aim of this study was to evaluate the applicability of ovum pick-up equipment for follicular fluid collection from various follicular structures (experiment 1) and for recovery of follicular fluid for acid-base balance analysis (experiment 2). An ultrasound scanner equipped with a 5-MHz convex transducer was used for transvaginal ultrasound-guided follicular aspiration. A 17-gauge, 60-cm aspiration needle was connected with a shortened aspiration line. The fluid was aspirated manually into a 2 ml plastic syringe at a speed of approximately 0.2 ml/s. The success of aspiration was higher in ovarian cysts (100%) and single follicles larger than 13 mm (76.7%) compared to single follicles smaller than 12 mm (20%, p { 0.001). The success of aspiration ofmultiple follicles on day 4 (diameter of 7-9 mm) was higher (90.9%) compared to follicles on day 2 (diameter of 4-6 mm) (66.7%, p { 0.05) in experiment 1. The fluid from ovarian cysts } 25 mm in diameter was aspirated in a two-step proce
Název v anglickém jazyce
Limitations of ultrasound guided follicular aspiration for analysis of ovarian follicular fluid in dairy cattle
Popis výsledku anglicky
The aim of this study was to evaluate the applicability of ovum pick-up equipment for follicular fluid collection from various follicular structures (experiment 1) and for recovery of follicular fluid for acid-base balance analysis (experiment 2). An ultrasound scanner equipped with a 5-MHz convex transducer was used for transvaginal ultrasound-guided follicular aspiration. A 17-gauge, 60-cm aspiration needle was connected with a shortened aspiration line. The fluid was aspirated manually into a 2 ml plastic syringe at a speed of approximately 0.2 ml/s. The success of aspiration was higher in ovarian cysts (100%) and single follicles larger than 13 mm (76.7%) compared to single follicles smaller than 12 mm (20%, p { 0.001). The success of aspiration ofmultiple follicles on day 4 (diameter of 7-9 mm) was higher (90.9%) compared to follicles on day 2 (diameter of 4-6 mm) (66.7%, p { 0.05) in experiment 1. The fluid from ovarian cysts } 25 mm in diameter was aspirated in a two-step proce
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GJ - Choroby a škůdci zvířat, veterinární medicina
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta veterinaria Brno
ISSN
0001-7213
e-ISSN
—
Svazek periodika
80
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
179-184
Kód UT WoS článku
000293898400007
EID výsledku v databázi Scopus
—