A comparison of quality parameters of fresh feline ejaculates collected by three different collection techniques
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16170%2F18%3A43876403" target="_blank" >RIV/62157124:16170/18:43876403 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1111/rda.13205" target="_blank" >http://dx.doi.org/10.1111/rda.13205</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/rda.13205" target="_blank" >10.1111/rda.13205</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparison of quality parameters of fresh feline ejaculates collected by three different collection techniques
Popis výsledku v původním jazyce
The aim of our study was to compare the quality parameters of fresh feline ejaculates collected by three different techniquesurethral catheterization after medetomidine administration (CT), electroejaculation (EE) and epididymal slicing after orchiectomy (EP). A total of 34 adult male cats (Felis catus) were included in the study. In all male cats, the sperm collection was performed under general anaesthesia by three collection methods in the following order: urethral catheterization, electroejaculation and epididymal slicing. The sperm parameters evaluated were as follows: volume, motility, viability, sperm concentration, total sperm count and morphological examination. The highest quality semen parameters were achieved using EE. The comparison of results of the evaluated sperm quality parameters from EE and EP showed significant differences only in one casethe percentage of head abnormalities and lower percentage of head abnormalities were achieved using EE compared to EP: 8.5% (3.0%-21.0%) versus 10.0% (4.0%-22.0%). Semen collected by CT rendered the lowest quality samples when compared to sperm samples collected by EE and EP, especially with respect to the motility and total sperm count which were significantly lower (p<0.001). Our study showed that sperm samples collected by EE and EP result in better quality of feline ejaculates compared to collection by CT from sperm samples collected from the same male cats. These results demonstrate the necessity of further research of urethral catheterization as a novel technique of semen collection in male cats.
Název v anglickém jazyce
A comparison of quality parameters of fresh feline ejaculates collected by three different collection techniques
Popis výsledku anglicky
The aim of our study was to compare the quality parameters of fresh feline ejaculates collected by three different techniquesurethral catheterization after medetomidine administration (CT), electroejaculation (EE) and epididymal slicing after orchiectomy (EP). A total of 34 adult male cats (Felis catus) were included in the study. In all male cats, the sperm collection was performed under general anaesthesia by three collection methods in the following order: urethral catheterization, electroejaculation and epididymal slicing. The sperm parameters evaluated were as follows: volume, motility, viability, sperm concentration, total sperm count and morphological examination. The highest quality semen parameters were achieved using EE. The comparison of results of the evaluated sperm quality parameters from EE and EP showed significant differences only in one casethe percentage of head abnormalities and lower percentage of head abnormalities were achieved using EE compared to EP: 8.5% (3.0%-21.0%) versus 10.0% (4.0%-22.0%). Semen collected by CT rendered the lowest quality samples when compared to sperm samples collected by EE and EP, especially with respect to the motility and total sperm count which were significantly lower (p<0.001). Our study showed that sperm samples collected by EE and EP result in better quality of feline ejaculates compared to collection by CT from sperm samples collected from the same male cats. These results demonstrate the necessity of further research of urethral catheterization as a novel technique of semen collection in male cats.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30502 - Other medical science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Reproduction in Domestic Animals
ISSN
0936-6768
e-ISSN
—
Svazek periodika
53
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1068-1074
Kód UT WoS článku
000443812400006
EID výsledku v databázi Scopus
2-s2.0-85052789997