Alternative measurement systems for recording cardiac activity in animals: a pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16170%2F22%3A43880397" target="_blank" >RIV/62157124:16170/22:43880397 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27240/22:10249870
Výsledek na webu
<a href="https://doi.org/10.1186/s40317-022-00286-y" target="_blank" >https://doi.org/10.1186/s40317-022-00286-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s40317-022-00286-y" target="_blank" >10.1186/s40317-022-00286-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Alternative measurement systems for recording cardiac activity in animals: a pilot study
Popis výsledku v původním jazyce
Monitoring and assessing cardiac activity in animals, especially heart rate variability, has been gaining importance in the last few years as an indicator of animal health, well-being and physical condition. This pilot study tested the sensors based on ballistocardiography sensing the mechanical vibrations caused by the animal's cardiovascular system, which have proved useful in measuring cardiac activity in humans. To verify the accuracy of these measurement systems, the conventional measurements based on electrocardiography were carried out and the outcomes were compared. The main objectives were to verify the suitability of these sensors in measuring cardiac activity in animals, to determine the advantages and disadvantages of these sensors, and to identify future challenges. Measurements were performed on various animals, specifically a goat, a cow, a horse, and a sheep. Electrocardiographic measurement, which has demonstrated high accuracy in procedures for animals, was used as the study's gold standard. A disadvantage of this method, however, is the long time required to prepare animals and shear spots to attach electrodes. The accuracy of a ballistocardiographic sensor was compared to reference electrocardiographic signals based on Bland-Altman plots which analysed the current heart rate values. Unfortunately, the ballistocardiographic sensor was highly prone to poor adhesion to the animal's body, sensor movement when the animal was restless, and motion artefacts. Ballistocardiographic sensors were shown only to be effective with larger animals, i.e., the horse and the cow, the size of these animals allowing sufficient contact of the sensor with the animal's body. However, this method's most significant advantage over the conventional method based on electrocardiography is lower preparation time, since there is no need for precise and time-demanding fixation of the sensor itself and the necessity of shaving the animal's body.
Název v anglickém jazyce
Alternative measurement systems for recording cardiac activity in animals: a pilot study
Popis výsledku anglicky
Monitoring and assessing cardiac activity in animals, especially heart rate variability, has been gaining importance in the last few years as an indicator of animal health, well-being and physical condition. This pilot study tested the sensors based on ballistocardiography sensing the mechanical vibrations caused by the animal's cardiovascular system, which have proved useful in measuring cardiac activity in humans. To verify the accuracy of these measurement systems, the conventional measurements based on electrocardiography were carried out and the outcomes were compared. The main objectives were to verify the suitability of these sensors in measuring cardiac activity in animals, to determine the advantages and disadvantages of these sensors, and to identify future challenges. Measurements were performed on various animals, specifically a goat, a cow, a horse, and a sheep. Electrocardiographic measurement, which has demonstrated high accuracy in procedures for animals, was used as the study's gold standard. A disadvantage of this method, however, is the long time required to prepare animals and shear spots to attach electrodes. The accuracy of a ballistocardiographic sensor was compared to reference electrocardiographic signals based on Bland-Altman plots which analysed the current heart rate values. Unfortunately, the ballistocardiographic sensor was highly prone to poor adhesion to the animal's body, sensor movement when the animal was restless, and motion artefacts. Ballistocardiographic sensors were shown only to be effective with larger animals, i.e., the horse and the cow, the size of these animals allowing sufficient contact of the sensor with the animal's body. However, this method's most significant advantage over the conventional method based on electrocardiography is lower preparation time, since there is no need for precise and time-demanding fixation of the sensor itself and the necessity of shaving the animal's body.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
40301 - Veterinary science
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000867" target="_blank" >EF16_019/0000867: Centrum výzkumu pokročilých mechatronických systémů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Animal Biotelemetry
ISSN
2050-3385
e-ISSN
2050-3385
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
21
Strana od-do
nestrankovano
Kód UT WoS článku
000788298900001
EID výsledku v databázi Scopus
—