Assessment of ecosystem contamination in flooded areas of Moravia, Czech Republic during the period 1997 - 2001
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F02%3A00000548" target="_blank" >RIV/62157124:16270/02:00000548 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of ecosystem contamination in flooded areas of Moravia, Czech Republic during the period 1997 - 2001
Popis výsledku v původním jazyce
Concentrations of polychlorinated biphenyls (PCB) indicator congeners were determined using high resolution gas chromatography equipped with electron capture detection (HRGC/ECD) in water and sediment samples collected in flooded areas of Moravia, CzechRepublic. Floods occured in the sampling areas during the years 1997 and 1998. The sampling sites were collected five times yearly in the same period of each year from 1997 until 2001. From each sampling site 6 samples were collected. This allowed the assessment and following comparison of contamination levels. Samples were extracted with non-polar and partly with polar solvents and cleaned using the solid phase extraction and column chromatography on a mixed column comprised of florisil and aluminium oxide. Separation by HRGC/ECD was carried out with two columns (Hewlett-Packard HP 5 and J W Scientific DB-MS) using the split/splitless technique with optimal temperature programme (Hewlett Packard HP 6890). Quantitative evaluation was ca
Název v anglickém jazyce
Assessment of ecosystem contamination in flooded areas of Moravia, Czech Republic during the period 1997 - 2001
Popis výsledku anglicky
Concentrations of polychlorinated biphenyls (PCB) indicator congeners were determined using high resolution gas chromatography equipped with electron capture detection (HRGC/ECD) in water and sediment samples collected in flooded areas of Moravia, CzechRepublic. Floods occured in the sampling areas during the years 1997 and 1998. The sampling sites were collected five times yearly in the same period of each year from 1997 until 2001. From each sampling site 6 samples were collected. This allowed the assessment and following comparison of contamination levels. Samples were extracted with non-polar and partly with polar solvents and cleaned using the solid phase extraction and column chromatography on a mixed column comprised of florisil and aluminium oxide. Separation by HRGC/ECD was carried out with two columns (Hewlett-Packard HP 5 and J W Scientific DB-MS) using the split/splitless technique with optimal temperature programme (Hewlett Packard HP 6890). Quantitative evaluation was ca
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DK - Kontaminace a dekontaminace půdy včetně pesticidů
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Symposium on the Environment and Analytical Chemistry
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
72
Název nakladatele
neudán
Místo vydání
Plymount
Místo konání akce
Plymount
Datum konání akce
1. 1. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—