Automatizovaná elektrochemická analýza těžkých kovů ve vybraných potravinách
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F08%3A00001779" target="_blank" >RIV/62157124:16270/08:00001779 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automated electrochemical analysis of haevy metals in selected foodstuffs.
Popis výsledku v původním jazyce
Increasing concentration of heavy metals in the environment is a serious problem for human and animal health protection and production of foodstuff in many countries around the world. Accordingly, methods for easy and quick detection of heavy metals at very low concentrations in environmental and biological samples are highly appreciated for assurance of disposals against acute intoxications and, first of all, against long-time exposure that may lead to many diseases or even death. Electrochemical techniques have very low detection limits for heavy metals, however suffer from the lack of automated analysis of large set of samples. The aim of this work was to utilize unique automated electrochemical analyser for simultaneous detection of zinc(II), cadmium(II), lead(II), arsenic(III) and copper(II) ions. Materials and methods. Electrochemical measurements were performed with 747 VA Stand instrument connected to 746 VA Trace Analyzer and 695 Autosampler (Metrohm, Switzerland), using a sta
Název v anglickém jazyce
Automated electrochemical analysis of haevy metals in selected foodstuffs.
Popis výsledku anglicky
Increasing concentration of heavy metals in the environment is a serious problem for human and animal health protection and production of foodstuff in many countries around the world. Accordingly, methods for easy and quick detection of heavy metals at very low concentrations in environmental and biological samples are highly appreciated for assurance of disposals against acute intoxications and, first of all, against long-time exposure that may lead to many diseases or even death. Electrochemical techniques have very low detection limits for heavy metals, however suffer from the lack of automated analysis of large set of samples. The aim of this work was to utilize unique automated electrochemical analyser for simultaneous detection of zinc(II), cadmium(II), lead(II), arsenic(III) and copper(II) ions. Materials and methods. Electrochemical measurements were performed with 747 VA Stand instrument connected to 746 VA Trace Analyzer and 695 Autosampler (Metrohm, Switzerland), using a sta
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Vitamins 2008 - Nutrition and Diagnostics
ISBN
978-80-7318-708-8
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Univerzita Tomáše Bati ve Zlíně
Místo vydání
Zlín
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—