Simultaneous determination of ten anticoagulant rodenticides in tissues by column-switching UHPLC-ESI-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F15%3A43873776" target="_blank" >RIV/62157124:16270/15:43873776 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00216-015-8954-1" target="_blank" >http://dx.doi.org/10.1007/s00216-015-8954-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-015-8954-1" target="_blank" >10.1007/s00216-015-8954-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous determination of ten anticoagulant rodenticides in tissues by column-switching UHPLC-ESI-MS/MS
Popis výsledku v původním jazyce
This paper describes the development of a method for the simultaneous determination of ten anticoagulant rodenticides (coumafuryl, warfarin, pindone, coumatetralyl, coumachlor, difenacoum, bromadiolone, brodifacoum, chlorophacinone and flocoumafen) in the liver and kidney based on column-switching liquid chromatography coupled with heated electrospray ionization tandem mass spectrometry. The simple sample preparation includes extraction with methanol. A C-18 trapping column was used for online solid-phase extraction before analytical separation with the mobile phase comprising a mixture of 0.1 % formic acid in water, methanol and acetonitrile. Chromatographic separation was achieved using a Thermo Hypersil ultra high-performance liquid chromatography (UHPLC) C-18 column with the mobile phase consisting of 5 mM ammonium formate buffer (pH = 9) and methanol. The column-switching procedure ensured no matrix effects during electrospray ionization (ESI). Extraction recoveries ranged between
Název v anglickém jazyce
Simultaneous determination of ten anticoagulant rodenticides in tissues by column-switching UHPLC-ESI-MS/MS
Popis výsledku anglicky
This paper describes the development of a method for the simultaneous determination of ten anticoagulant rodenticides (coumafuryl, warfarin, pindone, coumatetralyl, coumachlor, difenacoum, bromadiolone, brodifacoum, chlorophacinone and flocoumafen) in the liver and kidney based on column-switching liquid chromatography coupled with heated electrospray ionization tandem mass spectrometry. The simple sample preparation includes extraction with methanol. A C-18 trapping column was used for online solid-phase extraction before analytical separation with the mobile phase comprising a mixture of 0.1 % formic acid in water, methanol and acetonitrile. Chromatographic separation was achieved using a Thermo Hypersil ultra high-performance liquid chromatography (UHPLC) C-18 column with the mobile phase consisting of 5 mM ammonium formate buffer (pH = 9) and methanol. The column-switching procedure ensured no matrix effects during electrospray ionization (ESI). Extraction recoveries ranged between
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GJ - Choroby a škůdci zvířat, veterinární medicina
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
407
Číslo periodika v rámci svazku
25
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
7849-7854
Kód UT WoS článku
000361633700031
EID výsledku v databázi Scopus
—