Measurement of temperature of the canine eye in relation to the stress
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F24%3A43881575" target="_blank" >RIV/62157124:16270/24:43881575 - isvavai.cz</a>
Výsledek na webu
<a href="https://fvhe.vetuni.cz/files/upload/733/KMVP" target="_blank" >https://fvhe.vetuni.cz/files/upload/733/KMVP</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of temperature of the canine eye in relation to the stress
Popis výsledku v původním jazyce
Infrared thermography is used to assess stress in dogs and other animals based on changes in surface eye temperature. However, there are factors not related to stress that can affect measurement, so it is necessary to standardize measurement procedure. The aim of this study was to assess the effect of the measurement location on the value of the detected surface temperature in a dog. Measurement of the eye surface temperature by using a infrared thermography was carried out in 5 phases (waiting room after 5 and 10 minutes, examination room before, during and after treatment), the surface temperature of the lacrimal caruncle and the hottest point of the left and right eye was recorded. The results show that the average temperatures of the left and right eye were not significantly different (p > 0.05) and the temperatures of the lacrimal caruncle and the hottest point of both eyes significantly correlated (p ˂ 0.05). Therefore, it is possible to use both the lacrimal caruncle or the hottest point of the left or right eye for stress assessment.
Název v anglickém jazyce
Measurement of temperature of the canine eye in relation to the stress
Popis výsledku anglicky
Infrared thermography is used to assess stress in dogs and other animals based on changes in surface eye temperature. However, there are factors not related to stress that can affect measurement, so it is necessary to standardize measurement procedure. The aim of this study was to assess the effect of the measurement location on the value of the detected surface temperature in a dog. Measurement of the eye surface temperature by using a infrared thermography was carried out in 5 phases (waiting room after 5 and 10 minutes, examination room before, during and after treatment), the surface temperature of the lacrimal caruncle and the hottest point of the left and right eye was recorded. The results show that the average temperatures of the left and right eye were not significantly different (p > 0.05) and the temperatures of the lacrimal caruncle and the hottest point of both eyes significantly correlated (p ˂ 0.05). Therefore, it is possible to use both the lacrimal caruncle or the hottest point of the left or right eye for stress assessment.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
40301 - Veterinary science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXVI. konference mladých vědeckých pracovníků s mezinárodní účastí: Sborník příspěvků
ISBN
978-80-7305-957-6
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
33-35
Název nakladatele
Veterinární univerzita Brno
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
5. 6. 2024
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—